en_BA_PosCon_OXE7.docx
28/75
Baumer Electric AG
04.01.2021 15:33/adr V1.3 ANW_81125407
Frauenfeld, Switzerland
5.3
LIVE MONITOR
The installation conditions can be checked using LIVE MONITOR. The sensor continuously measures the
angle and the distance of the optical axis from the measuring level and outputs the values. This makes
installation much easier and also points out installation errors.
LIVE MONITOR
15.7° 220mm
Measured angle in ° (right
angle to reference
surface = 0°)
NOTE
An angle of 0° means that the sensor is at a right angle to the reference surface.
Distance from
the reference
surface
Distance
Right
Left
Angle