
en_BA_PosCon_OXE7.docx
43/75
Baumer Electric AG
04.01.2021 15:33/adr V1.3 ANW_81125407
Frauenfeld, Switzerland
5.10
DIGITAL OUT
With Pin 4 (out), the user has a configurable switching output.
It can be defined as a single switching point (threshold) or a window. Pin 4 is activated when the value (point
or window) is exceeded or not reached (active high or active low depending on the setting). The hysteresis for
a reliable switching signal is 0.5 mm.
5.10.1
DIGITAL OUT
Whether Pin 4 is to be operated as a
threshold
(with a switch point) or as a
window
(window function) is
defined here.
5.10.2
SWITCH POINT
The switch point is selected in mm using the arrow keys. The point must be within the measuring range.
5.10.3
WINDOW P1
Window point 1 (for the WINDOW mode) is selected in mm using the arrow keys. The point must be within the
measuring range. The window must be > 2 mm.
5.10.4
WINDOW P2
Window point 2 (for the WINDOW mode) is selected in mm using the arrow keys. The point must be within the
measuring range. The window must be > 2 mm.
5.10.5
LEVEL
The output can be set to
Active High
or
Active Low
(inverted) here.
LEVEL: Active high
THRESHOLD in mm
WINDOW POINT 1
WINDOW POINT 2
WINDOW
0 mm
DIGITAL OUT: THRESHOLD
DIGITAL OUT: WINDOW
0 mm
LEVEL: Active low
Signal low
Signal high
Signal low
Signal high
Range
Minus (-)
Range
Plus (+)
Range
Minus (-)
Range
Plus (+)
Left
Right
Left
Right