en_BA_PosCon_OXE7.docx
29/75
Baumer Electric AG
04.01.2021 15:33/adr V1.3 ANW_81125407
Frauenfeld, Switzerland
5.4
MEASUREMENT TYPE
The detected edges can be output in various ways, for example as simple edges (distance of the desired
edge in mm from the center of the measuring range) or also the width or center of an object as a value in mm,
calculated from two edges.
The measuring modes and their calculation are described below.
5.4.1
Edge L rise
The edge of the first rising flank from the left.
Distance in mm measured from the center of the measuring range of the sensor to the edge.
5.4.2
Edge L fall
The edge of the first falling flank from the left.
Distance in mm measured from the center of the measuring range of the sensor to the edge.
Measuring value
in mm
-
+
Left
Right
Right
Left
-
+
Left
Right
Measuring value
in mm
-
+
Measuring value
in mm
-
+
Left
Right
Right
Left
-
+
Left
Right
-
+
Measuring value
in mm