ELECTRICAL CONNECTION / CONNECTING HMCP16 TO HMCK16
MB168T1EN - 11184527, 19A2, Baumer_HMC16-T1_II_EN 15/40
8
*
7
*
9
*
Hand-tight
View X
6.3
Connecting HMCP16 to HMCK16
6.4
Terminal significance
+UB Voltage supply
0
V
Ground
A+ HTL/TTL/SinCos channel 1
A– HTL/TTL/SinCos channel 1 inverted
B+ HTL/TTL/SinCos channel 2 (offset by 90° to channel 1)
B– HTL/TTL/SinCos channel 2 inverted
R+ HTL/TTL/SinCos zero pulse (reference signal)
R– HTL/TTL/SinCos zero pulse inverted
nE (TTL) Error output TTL level
nE (HTL) Error output HTL level
fA+ Frequency output channel 1
fA– Frequency output channel 1 inverted
fB+ Frequency output channel 2 (offset by 90° to frequency output channel 1)
fB– Frequency output channel 2 inverted
0 V (nE) Ground for error output
CL+ Clock+ (SSI)
CL– Clock– (SSI)
DA+ Data+ (SSI)
DA– Data– (SSI)
dnu Do not use
* See