6.2.5. Terminal assignment
Pin
Terminal
Explanation
M12-connector (male/female)
1
GND
Ground connection relating to UB
2
UB
Supply voltage 10...30 VDC
3
GND
Ground connection relating to UB
4
CAN_H
CAN Bus signal (dominant High)
5
CAN_L
CAN Bus signal (dominant Low)
Terminals with the same designation are connected to each other internally and identical in their functions.
Maximum load on the internal clamps UB-UB and GND-GND is 1 A each.
6.3. Status LEDs (status indicators)
An integrated DUO-LED is provided on the back of inclination sensor housing.
LED green
LED red
Status
Off
Off
No supply voltage
Flashing
Off
Pre-operational Mode
On
Off
Operational Mode
On
On
Stopped/Prepared Mode
Off
Flashing
Alert/warning
Off
Off
Error