![Baumer GNAMG Series Manual Download Page 16](http://html.mh-extra.com/html/baumer/gnamg-series/gnamg-series_manual_2710742016.webp)
Manual_GNAMG_CANopen_EN.doc
16/41
Baumer IVO GmbH & Co. KG
21.11.12
Villingen-Schwenningen, Germany
Setting the BitTiming
7E5h
13h
tableSel tableInd reserved
7E4h
13h
ErrCode SpecError reserved
TableSel
: Selects BitTiming table
0
: Standard CiA Bit Timing table
1..127 : Reserved for CiA
128..255 : Manufacturer-specific tables
TableInd
: BitTiming entry in table selected (see table below).
ErrorCode
: 0=OK; 1=BitTiming beyond the range; 2..254=reserved; 255
SpecificError
SpecificError
: If ErrorCode=255
application-specific error code.
Standard CiA Table
Baud rate
Table Index
1000 kBaud
0
800 kBaud
1
500 kBaud
2
250 kBaud
3
125 kBaud
4
100 kBaud
5
50 kBaud
6
20 kBaud
7
10 kBaud
8
Saving the configuration protocol
By this protocol the configured parameters are saved in EEPROM.
7E5h
17h
reserved
7E4h
17h
ErrCode SpecError Reserved
ErrorCode
: 0=OK;1=saving not supported;2=acess error;3..254=reserved;255
specificError
SpecificError
: If ErrorCode=255
application-specific error code.
Activate BitTiming Parameters
The new BitTiming parameters are activated by command specifier 15h.
7E5h
15h
Switch Delay
Reserved
Switch Delay
: Delay in ms of slave reset.
After the delay the inclination sensor will register with the new baud rate.
VendorId request
Requesting the VendorId of a selected inclination sensor
7E5h
5Ah
Reserved
7E4h
5Ah
32 Bit Vendor ID
Reserved
VendorID
: = ECh