![Baumer GNAMG Series Manual Download Page 28](http://html.mh-extra.com/html/baumer/gnamg-series/gnamg-series_manual_2710742028.webp)
Manual_GNAMG_CANopen_EN.doc
28/41
Baumer IVO GmbH & Co. KG
21.11.12
Villingen-Schwenningen, Germany
Object 2300
Customer EEPROM section
SubIndex
0
Data type
Unsigned 8
Access
ReadOnly
Default
8h
EEPROM
No
Meaning
Any optional data can be saved in this object
Parameter
8
SubIndex
1...8
Data type
Unsigned 16
Access
ReadWrite
Default
0h
EEPROM
Yes
Meaning
One 16 bit parameter per each subindex (load in EEPROM by object 1010h)
Parameter
0
Object list according to DS 410
Object 6000
Resolution
SubIndex
0
Data type
Unsigned 16
Access
ReadWrite
Default
0001h =
0.001°
EEPROM
Yes
Meaning
Resolution
Parameters
0001h =
0.001°
000Ah =
0.01°
0064h =
0.1°
03E8h =
1.0°
Object 6110
Slope angle Y- axis (Slope long) (not at 360° sensor)
SubIndex
0
Data type
Integer 32
Access
ReadOnly
Default
EEPROM
No
Meaning
Slope angle
Parameters
Value range
Depending on the device type (measuring range) and parameter in 6000h
(resolution):
(+measuring range)/resolution ... to ... (-measuring range)/resolution
Example:
measuring range = ±30°
Resolution = 0,001
Value range: +30000...-30000