Manual_GNAMG_CANopen_EN.doc
26/41
Baumer IVO GmbH & Co. KG
21.11.12
Villingen-Schwenningen, Germany
Object 1A00
PDO1 Mapping
SubIndex
0
Data type
Unsigned 8
Access
ReadOnly
Default
0
EEPROM
No
Meaning
Maximum supported subindex
Parameter
2
SubIndex
1
Data type
Integer 32
Access
ReadOnly
Default
61100020h slope angle Slope Long , Y-axis
EEPROM
No
Meaning
Inhalt PDO1
Parameters
61100020h slope angle Slope Long , Y-axis
SubIndex
2
Data type
Integer 32
Access
ReadOnly
Default
61200020h slope angle Slope Lateral , X-axis
EEPROM
No
Meaning
Contents PDO1
Parameters
61200020h slope angle Slope Lateral , X-axis
Object 2100
Baud rate
SubIndex
0
Data type
Unsigned 8
Access
ReadWrite
Default
2 = 50 kBaud
EEPROM
Yes
Meaning
Read or set a new sensor baud rate
After the setting operation the parameters must be stored in EEPROM by
object 1010h, followed by a sensor re-init.
Parameters
0
10 kBaud
1
20 kBaud
2
50 kBaud
3
100 kBaud
4
125 kBaud
5
250 kBaud
6
500 kBaud
7
800 kBaud
8
1000 kBaud
Object 2101
Node-ID
SubIndex
0
Data type
Unsigned 8
Access
ReadWrite
Default
1
EEPROM
Yes
Meaning
Read or set a new sensor Node-ID.
After the setting operation the parameters must be stored in EEPROM by
object 1010h, followed by a sensor re-init.
Parameters
1..127