G 120 II V
Page 58
1st Edition, Rev. 0 Chg. 2
4.1.4.2
Purification System Dataplate
Refer to the compressor unit purification system data plate (Figure 4-3) on the compressor front to deter-
mine your purification system model and specifications.
4.1.4.3
Cartridge Installation Dataplate
The function performed by each chamber in the purification system is determined by the type of cartridge
installed in that chamber. Refer to the cartridge installation data plate on the chamber to determine the
purpose and part number of the cartridge installed in that chamber. (Figure 4-3).
4.1.5
Breathing Air Purification System Configurations
Purification System
Number and Type of Cartridges
Processing Capacity
Dryer
Purification
Securus
®
cubic ft (ft)
3
P0
Combined
3,200
P1 …
1
…
15,000
P2 …
1
…
40,000
P2 with Securus
®
…
…
1
67,000
P4 1
1
…
60,000
P5
1
1
…
90,000
P5 with Securus
®
1
…
1
150,000
P10
2
1
140,000
P10 with Securus
®
2
…
1
230,000
P12
a
a.
P12 and P14 have the Securus
®
Electronic Moisture Monitor System as standard equipment.
1
1
420,000
P14
a
2
1
650,000
P31
Combined
11,760
P41
…
1
28,700
P41 with Securus
®
…
…
1
47,000
P42
1
1
…
64,000
P42 with Securus
®
1
…
1
107,000
P43
2
1
…
100,000
P43 with Securus
®
2
…
1
164,000
P81
1
1
124,000
P81 with Securus
®
1
...
1
198,000