START-UP / SHUT-DOWN
BG 25 / 2011 /
2254_BG25_en_0000498763_V01
6 - 2
6.1.3
Daily Start-Up
6.1.3.1 Starting the Equipment
CAUTION
Risk of damaging the equipment!
Observe instructions in the manual of the base machine!
Set the battery main switch to "ON" position.
Set all controls to "0" position.
Pull the Emergency STOP button.
Start the engine by turning the ignition key.
CAUTION
Risk of damaging the engine!
Allow cold engine to warm up at idle speed for approx. 10 minutes!
Move the safety stick of the pilot control to "ON" position.