MNL- 0345
Page 74
Section 4
Base Edition
4.1.5.3
Cartridge Installation Dataplate
The function performed by each chamber in the purification system is determined by the type of cartridge
installed in that chamber. Refer to the cartridge installation dataplate on the chamber to determine the
purpose and part number of the cartridge installed in that chamber. (See Figure 4.1-4).
4.1.6
Cartridge Operating Life
Every BAUER Purification System is designed to process a certain volume of air before the cartridges
require replacement. By using special test equipment that measures the quality of air at the outlet any
quality reduction may be detected. However as most compressor owners do not have this test equipment
the recommended method of determining cartridge operating life is to maintain a written record of the
volume of air processed by the purification system.
Each BAUER compressor block is rated to produce a standard volume of air per minute and by using this
number and the air processing capability of the purification system it is possible to calculate the maxi-
mum operating hours before the cartridges need to be replaced. See Paragraph 4.1.6.1 for the method of
determining this figure.
Figure 4.1-3
Purification System Dataplate (typical)
Figure 4.1-4
Cartridge Installation Dataplate (typical)
BAUER
COMPRESSORS
MODEL NO.
MAX. PRESSURE
AIR PROCESSED
O-RING
BACK-UP RING
psig
cu. ft.
LBL-
PURIFICATION
SYSTEM
BAUER
COMPRESSORS
CARTRIDGE FOR
CARTRIDGE NO.
LBL-
CARTRIDGE TO BE
INSTALLED