AW00101510000
Day/Night Functionality
Basler IP Fixed Dome Cameras
97
Fig. 16: Input Used to Control IR-Cut Filter Position
Illuminator
Internal switch
associated with
a photocell
RS-485 Gnd
(isolated)
B-
A+
DC Out
VDC
Camera
Power Gnd
(isolated)
Camera
+5
VDC
+5
VDC
1 k
Ω
(Set as an output)
(Set as an input)
I/O-0
I/O-1
1 k
Ω
Heater Off
Isolated I/O Circuit
Isolated
RS-485
Circuit
I/O Gnd
(isolated)
Isolated Alternate
Camera Power Circuit
(Outdoor dome cameras only)