INTRODUCTION 

Thank you for choosing  QUASAR-C ice cube makers. 

You  have  purchased  one of  the  most  reliable ice-making  products on  the  market today.  Carefully  read  the 

instructions  contained  in  this  manual  since  they  provide  important  information  relative  to  safety  during 

installation, use, and maintenance. 

WARNINGS 

This appliance should be installed by approved Technical Service Personnel. 

This plug should be accessible at all times. 

To reduce the risk of electrical shock, ALWAYS disconnect the machine BEFORE cleaning or maintaining 

the  equipment.  Do  not  attempt  to  install,  service,  or  modify  this  machine.  Improper  use  by  other  than 

specially trained technicians is extremely dangerous and may result in a fire or electric shock.  

This machine should not be placed outdoors or exposed to rain. 

Connect to drinking water mains. 

This appliance is not intended for use by young children or infirm persons without supervision. 

Young children should be supervised to ensure that they do not play with the appliance. 

IMPORTANT!

 

•  DO  NOT  ATTEMPT  TO  SERVICE  THIS  MACHINE  AS  IT  IS  DANGEROUS  AND  COULD 

CAUSE SEVERE DAMAGE TO THE UNIT.  

•SERVICE SHOULD ONLY BE CARRIED OUT BY TRAINED, CERTIFIED PERSONNEL.  

•WE  STRONGLY  RECOMMEND  USING  ONLY  ORIGINAL  REPLACEMENT  PARTS 

AVAILABLE FROM AN AUTHORIZED  DISTRIBUTOR. 

•WASTE  AND  OTHER  MATERIAL  SHOULD  BE  DISPOSED  OF  ACCORDING  TO  LOCAL 

REGULATIONS AND PROCEDURES FOR WASTE DISPOSAL. 

•CLEANING AND MAINTENANCE ARE NOT COVERED BY THE WARRANTY. 

 

 

Summary of Contents for QUASAR 90 C

Page 1: ...C QUASAR 50 C QUASAR 60 C QUASAR 90 C QUASAR 130 C QUASAR 150 C MODULARS MQ 200 CAREFULLY READ THE INSTRUCTIONS CONTAINED IN THIS MANUAL SINCE THEY PROVIDE IMPORTANT INFORMATION RELATIVE TO SAFETY DUR...

Page 2: ...nd serial number 13 Installation Recommended placement of unit 14 Water and drainage 14 Connecting unit to water source 15 Connecting unit to drain 15 Electrical connection 15 Operation principle Prel...

Page 3: ...than specially trained technicians is extremely dangerous and may result in a fire or electric shock This machine should not be placed outdoors or exposed to rain Connect to drinking water mains This...

Page 4: ...eight and diameter Easy to maintain and repair HOW IT WORKS When the machine is switched on the compressor and the agitator motor start the water entry valve opens and allows water into the production...

Page 5: ...full the pan stops in its downward movement as it touches the cubes so working the safety stop micro switch and switching off the machine Production will start again as soon as the cubes which detain...

Page 6: ...6...

Page 7: ...R 20 C 405 510 690 60 35 65 123 45 65 105 QUASAR 30 C 405 510 745 60 35 65 123 45 65 105 QUASAR 40 C 405 510 870 60 35 65 123 45 65 105 QUASAR 40S 50 C 515 555 870 60 42 74 123 65 75 105 QUASAR 60 C 5...

Page 8: ...8 STOCK THERMOSTAT WATER INLET ELECTRICAL CONNECTION...

Page 9: ...VERAGE 2 1 2 GR Kg cm2 Psi Kg cm2 Psi Kg cm2 Psi A A W W QUASAR 20C A 260 16 228 17 240 2 5 38 1 5 10 175 220 QUASAR 20C W 190 16 228 17 240 2 5 38 1 5 10 175 220 QUASAR 30C A 260 16 228 17 240 2 5 38...

Page 10: ...0 5 22 38 24 37 25 35 26 33 28 32 29 31 25 41 27 40 29 38 31 36 32 34 33 31 33 5 30 25 20 42 21 40 5 22 38 24 37 25 35 26 33 28 32 24 43 25 41 27 40 29 38 31 36 32 34 33 31 20 19 44 20 42 21 40 5 22 3...

Page 11: ...0 35 WATER TEMPERATURE C Water quality 500 ppm 240 Micromh cm QUASAR 150 C 45 24 99 26 92 28 85 29 81 30 79 31 77 32 74 40 23 103 24 99 26 92 28 85 29 81 30 79 31 77 35 22 108 23 103 24 99 26 92 28 85...

Page 12: ...r on all claims Serial number is located in the following three places Packing There is a label stick onto the cardboard packing bearing this serial number 1 Machine body On the machine s rear panel 1...

Page 13: ...ations if the premises where the machines is located are very dusty or smoky If possible make arrangements so that the machine may be moved front wise in order to carry out maintenance Recommended Pla...

Page 14: ...proper function In water cooled models condenser obstruction is likely Installation of a high quality water softener is recommended c CHLORINATED WATER Chlorine taste can be avoided by installing a c...

Page 15: ...pply Machine levelling Place machine where it is required and level the machine ONCE all four legs have been screwed on Space requirements There should be a 150 mm gap on sides and top of the machine...

Page 16: ...ater pressure adequate MAXIMUM 0 7 Kg cm2 MINIMUM 6 Kg cm2 ATTENTION Check that voltage and mains frequency are the same as in the rating plate Starting up Once preliminary check has been completed ve...

Page 17: ...28 Psi which is equivalent to a water exit temperature of 38 C below this pressure it will be difficult to unstick the cubes in the defrosting stage Above this pressure compressor life and ice product...

Page 18: ...nish ice production Pressure can be regulated by rotating screw on Pressure Control Valve clockwise to increase pressure One rotation equals 1 5 Kg cm2 Safety pressostat This Security device trips whe...

Page 19: ...mplete procedures on a monthly basis MAINTENANCE TABLE PROCEDURE MONTHLY QUARTERLY BIANNUAL YEARLY BIENNIAL DURATION Air condenser cleaning 0000 0000 30 minutes Water condenser cleaning 90 minutes Wat...

Page 20: ...istribute solution through condenser Solution is more effective at 35 40 C WARNING DO NOT USE HYDROCHLORIC ACID Air Condenser 1 Disconnect machine 2 Close water faucet 3 Clean condenser using a vacuum...

Page 21: ...t 5 minutes 9 Repeat 6 several times until water pan has been thoroughly rinsed WARNING Discard ice produced during cleaning procedure Cleaning the ice bin 1 Unplug the machine turn off water supply a...

Page 22: ...arate Always use the liquid phase valve at the end of condenser or accumulator for refills and purges When replacing a compressor wash inside of circuit with a suitable solvent pump dry with nitrogen...

Page 23: ...ace Klixon D Faulty compressor D Replace compressor 3 All the electrics work but the compressor Klixons cycles intermittently A Voltage too low A Check voltage B Dirty condenser B Clean condenser C Ob...

Page 24: ...n or pressostat faulty inlet cooling water valve D Check fan and re adjust pressostat or replace E Refrigerant charge too high or too low E Adjust F Faulty water inlet valve leaks and does not close f...

Page 25: ...tor micro switch badly connected or faulty A Connect or replace micro switch B Security micro badly connected or faulty B Connect or replace micro switch C Faulty rele C Replace rele 13 The evaporator...