background image

DEVICE INSTALATION

Instalation, setting, rebuilding for another gas type, putting into operation must be done by qualifi ed person 

who is competent for this and according to the valid standards. The device can be instalated in good ventilated 

room.When it is possible place the device under the fumehood to suck off the products of combustion. Air 

needy to the burning is 2m/3/h/kW ot the performance of the instaled device. 

The device can be instalated separately or in a set with devices of our production. Min. distance 10 cm 

from other subjects must be kept.It is also necessary to prevent our product from contact with combustible 

materials. In this case you must make corresponding changes to secure heat izolation of combustible parts 

(for example:place between the device and combustible material azbestos plate).

5

SAFETY MEASURES FROM THE STANDPOINT OF THE FIRE PROTECTION 

ACCORDING TO EN 061008 ČL. 21

 

• only adults can operate the device

• device must be safely used in common surroundings according to EN 332000-4-482; EN 332000-4-42

• device must be placed so as to stand or hang on the noncombustible surface. No subjects from combustible 

materials can be placed directly on the device or in distance which is shorter than safety distance (the 

shortest distance is 10 cm).

• safety distances from various materials of different degree of combustion and information about the degree 

of comb. of common building materials - see chart:

Chart:

Combustion degree of building materials classifi ed according to the combustion degree of materials and 

products (EN 730823)

A noncombustible  

 

granit, sandstone, concretes,bricks, ceramic wallfacing tiles, plaster

B uneasily combustible  

akumine, heraklite, lihnos, itavere

C1 hardly combustible  

leafy wood, plywood, sirkoklit, rare paper formica 

C2 middle combustible  

fi breboards, solodure, cork boards, rubber,fl oor-coverings

C3 easily combustible  

wood-fi breboards, polystyrene,polyurethane, PVC

Devices must be instalated in a safe way. When instaling you must respect corresponding project, safety and 

hygienic orders according to:

• EN 061008 fi re protection of local devices and sources of heat

• EN 332000 surrounding for electric devices

Summary of Contents for FTH - 30G

Page 1: ...STRUCTIONS FOR INSTALLATION AND USE Date 2012 mmm FTH 30G GL A3700331 FTR 30G GL FTH 60G GL A3700341 FTHR 60G GL FTH 90G GL FTHC 30G GL FTRC 30G GL FTHC 60G GL FTHRC 60G GL FTHC 90G GL GAS GRIDDLE PLATES ...

Page 2: ... CONFORMITY 3 INSTRUCTION FOR USE 10 CLEANING AND MAINTENANCE 11 DIE NORMENÜBEREINSTIMMUNGSDEKLARATION 12 GEBRAUCHSANWEISUNG 20 REINIGUNG UND WARTUNG 21 DÉCLARATION DE CONFORMITÉ 22 MODE D EMPLOI 29 ENTRETIEN 30 3 8 9 10 15 13 17 21 22 ...

Page 3: ... 30 GL 1x 4 0 kW 4 0 32 x 48 33 x 60 x 29 v FTR 30 GL 1x 4 0 kW 4 0 32 x 48 33 x 60 x 29 v FTH 60 GL 2x 4 0 kW 8 0 65 x 48 66 x 60 x 29 v FTHR 60 GL 2x 4 0 kW 8 0 65 x 48 66 x 60 x 29 v FTH C 30 GL 1x 4 0 kW 4 0 32 x 48 33 x 60 x 29 v FTR C 30 GL 1x 4 0 kW 4 0 32 x 48 33 x 60 x 29 v FTH C 60 GL 2x 4 0 kW 8 0 65 x 48 66 x 60 x 29 v FTHR C 60 GL 2x 4 0 kW 8 0 65 x 48 66 x 60 x 29 v FTH 90 GL 3x 4 0 ...

Page 4: ...refully because it contains important information about safety elements installation use these recommendations refer to this product this product corresponds with valid standards this guide must be properly deposited for future use keep the children away from manipulation with the product when selling or moving the product to another place it is necessary top make yourself sure that the staff or t...

Page 5: ... surroundings according to EN 332000 4 482 EN 332000 4 42 device must be placed so as to stand or hang on the noncombustible surface No subjects from combustible materials can be placed directly on the device or in distance which is shorter than safety distance the shortest distance is 10 cm safety distances from various materials of different degree of combustion and information about the degree ...

Page 6: ... This must be controlled on regular basis and changed if needed Every appliance must be equipped with shut off valve and quick shut off valve Quick shut off valve must be freely accessible and within reach of the device After installation is necessary to check whether there is a gas leak To find a gas leak you can use soapy water or spray for gas leak detection Do not use corrosive substances All ...

Page 7: ...ther the flame of the burner licks the thermoelement and whether it is blue we recommend to the user when using the device to proceed according to the instructions for use Regulation of the flame by the lower performance sporo Adjust the low performance sporo and then regulate the flame with screw which is situated in the body of the tap next to the tap shaft Process of regulation remove the regula...

Page 8: ...8 ...

Page 9: ...ng sell it to the salvage Wrapping foil give into the salvage containers for plastic Liquidation of the device after useful life Sell the device and it s parts to the salvage INDICATION Guarentee does not cover all consumption parts succumable to common wear rubber seals bulbs glas and plastic parts etc The guarantee does not refer to the devices which were not instaled in correspondance with inst...

Page 10: ...Dimension FT 30 G FT 60 G FT 90 G 23 ...

Page 11: ...FT 30 GL FT 90 GL 24 ...

Reviews: