background image

6

Instructions for sucking off the gas products of combustion

Type A devices (see the label with characteristics). Appliance of fi nish A, that is the appliance which is not 

made for being connected with the chimney or other device for sucking off the products of combustion out 

of the space where the appliance is situated. These appliances must be situated in the room with suffi cient 

ventilation  according  to  the  ČSN  12  7010:1986  and  ČSN  1207040:1986.  It  is  necessary  to  prevent  the 

accumulation of the harmful matters in big concentration (secure the requirement of hygienic standard for 

working surrounding sv. 39/78 guideline 46).

PIPE FOR GAS CONNECTION

It must fi rst determine if the appliance is made for the same type of gas that will be used and thus conforms 

to the indications on the label the type of gas to be used.

The conversion of gas pan to another type of gas you need to check if it corresponds to the type of gas 

bearing, which is recommended in this guide.

Connecting the appliance to the gas distribution must be towable to a steel or copper tube complying with 

applicable national requirements. This must be controlled on regular basis and changed if needed. Every 

appliance must be equipped with shut-off valve and quick shut-off valve. Quick shut-off valve must be freely 

accessible and within reach of the device. After installation, is necessary to check whether there is a gas leak. 

To fi nd a gas leak you can use soapy water or spray for gas leak detection.

Do not use corrosive substances!! All our appliances are carefully controlled. Gas type, pressure and of the 

categories listed named on the technical information plate. 

Liquid gas connection:

Pressure for liquid gas connection must be 28 or 30 mbar for propane/butane and 37 mbar for propane. It 

is necessary to check the technical label ,gauge the pressure and check the parameters of the nozzle is 

installed with the required parameters of the nozzle according to the manufacturer‘s. If the pressure is lower 

than 25mbar or higher than 37 mbar, THE APPLIANCE SHALL NOT TO BE CONNECTED.  

Gas Connection:

Pressure for methane connection must be 18 or 20 mbar. It is necessary to check the technical label ,gauge 

the pressure and check the parameters of the nozzle is installed with the required parameters of the nozzle 

according to the manufacturer‘s. If the gas pressure is lower than 15mbar or higher than 22,5 mbar, THE 

APPLIANCE SHALL NOT TO BE CONNECTED.  

Summary of Contents for FTH - 30G

Page 1: ...STRUCTIONS FOR INSTALLATION AND USE Date 2012 mmm FTH 30G GL A3700331 FTR 30G GL FTH 60G GL A3700341 FTHR 60G GL FTH 90G GL FTHC 30G GL FTRC 30G GL FTHC 60G GL FTHRC 60G GL FTHC 90G GL GAS GRIDDLE PLATES ...

Page 2: ... CONFORMITY 3 INSTRUCTION FOR USE 10 CLEANING AND MAINTENANCE 11 DIE NORMENÜBEREINSTIMMUNGSDEKLARATION 12 GEBRAUCHSANWEISUNG 20 REINIGUNG UND WARTUNG 21 DÉCLARATION DE CONFORMITÉ 22 MODE D EMPLOI 29 ENTRETIEN 30 3 8 9 10 15 13 17 21 22 ...

Page 3: ... 30 GL 1x 4 0 kW 4 0 32 x 48 33 x 60 x 29 v FTR 30 GL 1x 4 0 kW 4 0 32 x 48 33 x 60 x 29 v FTH 60 GL 2x 4 0 kW 8 0 65 x 48 66 x 60 x 29 v FTHR 60 GL 2x 4 0 kW 8 0 65 x 48 66 x 60 x 29 v FTH C 30 GL 1x 4 0 kW 4 0 32 x 48 33 x 60 x 29 v FTR C 30 GL 1x 4 0 kW 4 0 32 x 48 33 x 60 x 29 v FTH C 60 GL 2x 4 0 kW 8 0 65 x 48 66 x 60 x 29 v FTHR C 60 GL 2x 4 0 kW 8 0 65 x 48 66 x 60 x 29 v FTH 90 GL 3x 4 0 ...

Page 4: ...refully because it contains important information about safety elements installation use these recommendations refer to this product this product corresponds with valid standards this guide must be properly deposited for future use keep the children away from manipulation with the product when selling or moving the product to another place it is necessary top make yourself sure that the staff or t...

Page 5: ... surroundings according to EN 332000 4 482 EN 332000 4 42 device must be placed so as to stand or hang on the noncombustible surface No subjects from combustible materials can be placed directly on the device or in distance which is shorter than safety distance the shortest distance is 10 cm safety distances from various materials of different degree of combustion and information about the degree ...

Page 6: ... This must be controlled on regular basis and changed if needed Every appliance must be equipped with shut off valve and quick shut off valve Quick shut off valve must be freely accessible and within reach of the device After installation is necessary to check whether there is a gas leak To find a gas leak you can use soapy water or spray for gas leak detection Do not use corrosive substances All ...

Page 7: ...ther the flame of the burner licks the thermoelement and whether it is blue we recommend to the user when using the device to proceed according to the instructions for use Regulation of the flame by the lower performance sporo Adjust the low performance sporo and then regulate the flame with screw which is situated in the body of the tap next to the tap shaft Process of regulation remove the regula...

Page 8: ...8 ...

Page 9: ...ng sell it to the salvage Wrapping foil give into the salvage containers for plastic Liquidation of the device after useful life Sell the device and it s parts to the salvage INDICATION Guarentee does not cover all consumption parts succumable to common wear rubber seals bulbs glas and plastic parts etc The guarantee does not refer to the devices which were not instaled in correspondance with inst...