background image

PLACEMENT

The device must be instalated in well ventilated room what is necessary for regulation of the function of the 

device (technician must go by valid standard (ČSN....). If the device is situated close to the wall or if it is in 

contact with the furniture walls, these walls must resist the temperatures ranging to 60°C. Instalation, setting, 

putting into operation must be done by qualifi ed person who is competent for this and according to the valid 

standards.

Wrap up the device and check whether it was not damaged during transport. Settle the device on horizontal 

surface (max imbalance 2°).Settle the device under the fumehood to eliminate water steam and bad smell.

The device can be instalated separately or in a set with devices of our production. Min. distance 10 cm 

from other subjects must be kept.It is also necessary to prevent our product from contact with combustible 

materials. In this case you must make corresponding changes to secure heat izolation of combustible parts. 

Safety measures from the standpoint of the fi re protection according to ČSN 061008čl. 21:

PACKING AND DEVICE CHECK

 

The device leaves our stocks properly packed with appropriate symbols and labels. There are also appropriate 

instructions for use. In case the packing shows bad handling or damage, it must be reclaimed at transporter 

immediately by writing and signing of a damage protocol.

Important notice:

• this instructing guide must be read properly and carefully because it contains important information about 

safety elements, installation, use                            

• these recommendations refer to this product

• this product corresponds with valid standards

• this guide must be properly deposited for future use

• keep the children away from manipulation with the product 

• when selling or moving the product to another place it is necessary top make yourself sure that the staff 

or the professional service has got acquainted with control and installation instructions from enclosed guide 

• only authorised person can operate the product 

• it can not be switched on without supervision 

• we recommend to have the product checked by professional service min. once a year

• only original spare parts can be used for repairs

• the product can not be cleaned by the water jet or pressure shower

• by damage or break down disconnect all the feeders (water, gas, electricity) and call professional service

• producer refuses any responsibility in case of damages caused by wrong installation, by disobserving of 

above mentioned recommendations or by other use etc.  

MODEL

NOZZLE

Burner

12,8 kWh/kg

G 30/G 31

PROPAN / BUTAN 

28 - 30 mbar

12,8 kWh/kg

G 31

PROPAN 

37 mbar

12,8 kWh/kg

G 30/G 31

PROPAN / BUTAN 

50 mbar

9,45 kWh/m

3

 

G 20

Natural GAS

20 mbar

FEEDING

TUBE

GAS

FT**-30 

NOZZLE OF BURNER 1/100 MM

4,0 kW

93

93

77

135

G 1/2“

CONSUPTION

4,0 kW

0,546 kg/h 

0,546 kg/h 

0,546 kg/h 

0,74 m

3

/h

---

FT**-60 

NOZZLE OF BURNER 1/100 MM

2x 4,0 kW

93

93

77

135

G 1/2“

CONSUPTION

2x 4,0 kW

1,092 kg/h 

1,092 kg/h 

1,092 kg/h 

1,148 m

3

/h

---

Model

Burner

Power

(kW)

Dimensions of plate

(cm)

Dimensions

(cm)

FTH - 30 G

1x 4,0 kW

4,0

32 x 48

33 x 60 x 22 v

FTR - 30 G

1x 4,0 kW

4,0

32 x 48

33 x 60 x 22 v

FTH - 60 G

2x 4,0 kW

8,0

65 x 48

66 x 60 x 22 v

FTHR - 60 G

2x 4,0 kW

8,0

65 x 48

66 x 60 x 22 v

FTH-C - 30 G

1x 4,0 kW

4,0

32 x 48

33 x 60 x 22 v

FTR-C - 30 G

1x 4,0 kW

4,0

32 x 48

33 x 60 x 22 v

FTH-C - 60 G

2x 4,0 kW

8,0

65 x 48

66 x 60 x 22 v

FTHR-C - 60 G

2x 4,0 kW

8,0

65 x 48

66 x 60 x 22 v

FTH - 90 G

3x 4,0 kW

12,0

97 x 48

99 x 60 x 22 v

FTH - C - 90 G

3x 4,0 kW

12,0

97 x 48

99 x 60 x 22 v

BURNERS

FT**-90

NOZZLE OF BURNER 1/100 MM

3x 4,0 kW

93

93

77

135

G 1/2“

CONSUPTION

3x 4,0 kW

1,638 kg/h 

1,638 kg/h 

1,638 kg/h 

2,22 m

3

/h

---

Summary of Contents for FTH - 30G

Page 1: ...STRUCTIONS FOR INSTALLATION AND USE Date 2012 mmm FTH 30G GL A3700331 FTR 30G GL FTH 60G GL A3700341 FTHR 60G GL FTH 90G GL FTHC 30G GL FTRC 30G GL FTHC 60G GL FTHRC 60G GL FTHC 90G GL GAS GRIDDLE PLATES ...

Page 2: ... CONFORMITY 3 INSTRUCTION FOR USE 10 CLEANING AND MAINTENANCE 11 DIE NORMENÜBEREINSTIMMUNGSDEKLARATION 12 GEBRAUCHSANWEISUNG 20 REINIGUNG UND WARTUNG 21 DÉCLARATION DE CONFORMITÉ 22 MODE D EMPLOI 29 ENTRETIEN 30 3 8 9 10 15 13 17 21 22 ...

Page 3: ... 30 GL 1x 4 0 kW 4 0 32 x 48 33 x 60 x 29 v FTR 30 GL 1x 4 0 kW 4 0 32 x 48 33 x 60 x 29 v FTH 60 GL 2x 4 0 kW 8 0 65 x 48 66 x 60 x 29 v FTHR 60 GL 2x 4 0 kW 8 0 65 x 48 66 x 60 x 29 v FTH C 30 GL 1x 4 0 kW 4 0 32 x 48 33 x 60 x 29 v FTR C 30 GL 1x 4 0 kW 4 0 32 x 48 33 x 60 x 29 v FTH C 60 GL 2x 4 0 kW 8 0 65 x 48 66 x 60 x 29 v FTHR C 60 GL 2x 4 0 kW 8 0 65 x 48 66 x 60 x 29 v FTH 90 GL 3x 4 0 ...

Page 4: ...refully because it contains important information about safety elements installation use these recommendations refer to this product this product corresponds with valid standards this guide must be properly deposited for future use keep the children away from manipulation with the product when selling or moving the product to another place it is necessary top make yourself sure that the staff or t...

Page 5: ... surroundings according to EN 332000 4 482 EN 332000 4 42 device must be placed so as to stand or hang on the noncombustible surface No subjects from combustible materials can be placed directly on the device or in distance which is shorter than safety distance the shortest distance is 10 cm safety distances from various materials of different degree of combustion and information about the degree ...

Page 6: ... This must be controlled on regular basis and changed if needed Every appliance must be equipped with shut off valve and quick shut off valve Quick shut off valve must be freely accessible and within reach of the device After installation is necessary to check whether there is a gas leak To find a gas leak you can use soapy water or spray for gas leak detection Do not use corrosive substances All ...

Page 7: ...ther the flame of the burner licks the thermoelement and whether it is blue we recommend to the user when using the device to proceed according to the instructions for use Regulation of the flame by the lower performance sporo Adjust the low performance sporo and then regulate the flame with screw which is situated in the body of the tap next to the tap shaft Process of regulation remove the regula...

Page 8: ...8 ...

Page 9: ...ng sell it to the salvage Wrapping foil give into the salvage containers for plastic Liquidation of the device after useful life Sell the device and it s parts to the salvage INDICATION Guarentee does not cover all consumption parts succumable to common wear rubber seals bulbs glas and plastic parts etc The guarantee does not refer to the devices which were not instaled in correspondance with inst...

Page 10: ...Dimension FT 30 G FT 60 G FT 90 G 23 ...

Page 11: ...FT 30 GL FT 90 GL 24 ...

Reviews: