- 54 -
5.4.3 Switching the device on
Press the
(1)
button on the right side; on the front panel, the green
“ON” (2A)
indicator light and red
(2F)
closure time
(MED)
indicator switch on.
5.4.4 Settings
Setting sealing time
To set the sealing time, press the
“T”
key
(2F)
before the vacuum packing cycle.
The set sealing time is saved
until:
-
the sealing time is set once again;
-
the
STOP
key is pressed;
To deactivate the device, move the switch to
“O”
or unplug it.
The position of the red switch on the button shows the set closure time:
-
MIN
(red control indicator light switches on) corresponds to a minimum closure
time recommended when performing several closures;
-
MED
(middle red indicator light flashes) corresponds to medium closure time,
suitable for most applications; the device is set at automatic closure time
according to default settings.
-
MAX
(right red indicator light switches on) max. closure time recommended
when preserving moist food.
STOP/CANCEL key
– 2C
To stop the machine at any moment, press the
“STOP/CANCEL”
button
(2C)
,
Fig. A
.
Unlock the lid by turning one of the two knobs
(7)
of the
“Lock & Unlock System”
device.