- 41 -
e) Setting of the smallest flame
•
After switching to the different gas type it is required to change the small flame
settings for the individual burners.
Adjust it in the following way:
•
Ignite the burner according to the instructions in section 5.2.3 “Ignition of gas
burners”.
•
Turn the flame adjustment knob clockwise to the small flame position “ “.
•
Remove the adjustment knob.
•
When switching from the natural gas to LPG the fine
adjustment screw F (on the right) should be turned
clockwise with use of small screwdriver until obtaining
the required flame power.
•
When switching from PLG to the natural gas the fine
adjustment screw F (on the right) should be turned
counterclockwise with use of small screwdriver until
obtaining the required flame power.
•
Replace the knob and quickly turn it from the maximum position to the minimum
position and check the flame. Make sure that it still allows for correct heating of
the thermal element. If not, correct it. Make adjustments for all burners.
•
After the replacement or adjustment of the nozzles always make sure that the
flame is blue, stable, does not separate from the burner, and there is no back
burning while changing from the large flame to the small one.
CAUTION!
•
After switching to the different gas type always check tightness with use of
appropriate spray or water with soap (never use the open flame!).
•
After all replacement or adjustment activities reinstall all previously removed
parts to make the device ready for operation.
•
After the modification remove the plate with the adjustment values and replace
it with the new one for the new gas type.