background image

14

Manuale d’installazione e d’uso

2.     OPERATING INSTRUCTIONS

3.    CLEANING AND MAINTENANCE

3.1    Ordinary Maintenance

During the cleaning don’t wash the equipment with direct water spout. The cleaning must be executed when the 
equipment is cold. Before the cleaning disconnect the equipment. Take away all the oven displaceable elements and 
wash them. The stainless steel elements must be washed by hot water and neutral detergent. Rinse the plate by a 
soft cloth to remove any trace of detergent. Dry with care. Using abrasive and corrosive detergents you can cause 
damages to the stainless steel. 

LIGHTING BURNERS 

• 

Open main gas tap upstream of appliance.  

• 

Push and turn the knob from “closed” position to “maximun flame” and simultaneously press the piezoelec

-

tric ignition button a few times until the burner rmains lit. 

When first starting up, in order to keep the light ON, keep the knob pressed for about 10 seconds. When it is 
released, the  light should remain lighted, otherwise, repeat the operation. 

• 

Turn the knob to the “minimum flame” position to set a slower and more economical cooking procedure, if 

required.  

SWITCH-OFF

• 

To put the appliance out, switch the knob back to position “closed”.

• 

At the end of the working day, switch off the gas check valve upstream of the appliance.  

At regular intervals (at least once a year or more often in cases of frequent use), service the appliance thoroughly. 
This includes checking the gas circuit, checking parts for damage and if necessary lubricating the taps if they are 
difficult to use. Contact a specialised and experienced technician. A maintenance contract should be taken out with 
a centre approved by the company.  

If the appliance is not used for a long time or if it does not work or works irregularly, the gas stopcock upstream 
of the appliance must be shut off.  
All the parts of the appliance that are subject to wear can easily be accessed from the front of the appliance after 
removing the front.  
All the couplings use a dado and bicono, so great care must be taken in handling these components. If the part is 
damaged during dismantling or reassembly it must be replaced with a new one.  

3.2    Special Maintenance

3.2   

 Control and safety devices

EN

Summary of Contents for 131.7433

Page 1: ...TENANCE MA NUAL FOR GAS COOKING TOPS LIVRET D INSTRUCTIONS POUR L UTILISA TION ET L ENTRETIEN DE L ENSEMBLE POUR PLANS DE CUISSO GEBRAUCHS UND WARTUNGSANLEI TUNG FÜR GASHERDE MANUAL DE INSTRUCCIONES PARA EL USO Y EL MANTENIMIENTO PARA HOR NALLAS GAS REV 002 2012 IT FR EN ES DE 131 7433 131 7463 ...

Page 2: ...tion instructions 11 Check before installation 11 Checking thermal power 12 Checking gas pressure 12 1 INSTALLATION 16 1 1 Avertissements importants 16 1 2 Positionnement 16 1 3 Evacuation des produits de combustion 17 1 4 RACCORDEMENT DU GAZ 17 Prescriptions pour l installation 17 Controles a effectuer avant l installation 17 Controle de la puissance ther mique 18 Controle de la pression du gaz 1...

Page 3: ...steel surfaces have to be kept properly clean Clean the parts in stainless steel daily with warm soapy water then rinse thoroughly and dry carefully On no account should the stainless steel be cleaned with steel wool pads brushes or scrapers in standard steel in that they could deposit fer rous particles which by oxidising cause rust spots Stainless steel wool can if necessary be used in the direc...

Page 4: ...em faults must be carried out only by qualified personnel in accordance with current rules and standards The gas systems wiring and premises in which the appliances are installed must comply with current rules and standards In particular the air supply for burner combustion must be 2m3 h per kW of installed power Accident prevention fire prevention and anti panic measures in businesses open to the...

Page 5: ...opcocks or gate valves whose internal diameter is not less than the above con necting pipe After connecting the pipe make sure that the joints and couplings have no leaks Use soapy water or a purpose designed foam product to detect leaks NEVER USE NAKED LIGHTS Gas supply pressure must be measured at the pressure point Ref P after removing the sealing screw Use a flexible pipe connect a gauge e g a...

Page 6: ...oam products DO NOT SEARCH FOR LEAKS WITH NAKED LIGHTS Before delivering the appliance to the user check that it operates correctly instruct the user on how to use it 2 OPERATING INSTRUCTIONS The appliance must be used only for the purpose for which it was designed Any other use is improper During operation supervise the appliance Before starting up the appliance for the first time unpack it Check...

Page 7: ...n Turn the knob to the minimum flame position to set a slower and more economical cooking procedure if required SWITCH OFF To put the appliance out switch the knob back to position closed At the end of the working day switch off the gas check valve upstream of the appliance At regular intervals at least once a year or more often in cases of frequent use service the appliance thoroughly This includ...

Page 8: ...0 19 kW 1 498 2 011 2 x 3 5 kW 2 x 6 kW LPG694F 21 3 kW 1 680 2 254 2 x 3 5 kW 2 x 6 kW 1 x 2 3 kW LPG694E 19 2 2 kW 1 498 2 011 2 x 3 5 kW 2 x 6 kW 1 x 2 2 kW EL LPG696F 31 2 kW 2 460 3 302 3 x 3 5 kW 3 x 6 kW 1 x 2 3 kW LPG794F 21 3 kW 1 680 2 254 2 x 3 5 kW 2 x 6 kW 1 x 2 3 kW LPG4920D 9 5 kW 0 749 1 005 1 x 3 5 kW 1 x 6 kW LPG6940D 19 kW 1 498 2 011 2 x 3 5 kW 2 x 6 kW LPG794E 19 2 2 kW 1 498 ...

Reviews: