Manuale d’installazione e d’uso

During initial installation and during maintenance or adaptation to another type of gas nominal heat input must be 
measured. It can be measured by using the volumetric method with the aid of a litre counter or a chronometer. 
After checking connection pressure and the diameter of the burner injectors, measure the hourly flow of the gas and 
compare the recorded value with the value set out in the specifications table under the heading “gas consumption”. 
Deviation of ± 5% from nominal value is permitted. The appliance must be supplied with one of the types of gas 
whose properties and pressure are set out in the table below:  

C

hecking thermal power

TIPI DI GAS

PRESSIONE IN mbar.

NOM.

MIN MAX

GAS METANO G20

20

18

25

G.P.L.         G30/31 28-30/37 25/25 35/45

Connect the appliance to a special gas pipe with an internal 
diameter of at least 16 mm for G1/2” connections and a 
diameter of at least 20 mm for G3/4” connections. The cou

-

pling must be metal and the pipe may be rigid or flexible. 
Make  sure  that  the  flexible  metal  pipe  that  is  fitted  to 
the gas coupling does not touch overheated parts of the 
appliance and is not twisted. Use fixing clips that comply

with installation standards. Fit stopcocks or gate valves whose internal diameter is not less than the above con

-

necting pipe. After connecting the pipe, make sure that the joints and couplings have no leaks. Use soapy water 
or a purpose-designed foam product to detect leaks.  

NEVER USE NAKED LIGHTS!

  

Gas supply pressure must be measured at the pressure point (Ref. P) after removing the sealing screw . Use a 
flexible pipe, connect a gauge e.g. a liquid gauge that is accurate to 0.1 mbar) to the pressure point (and measure  

C

hecking gas pressure

 

the intake pressure whilst the appliance is operating. If 
the pressure reading does not fall within the upper and 
lower limits indicated on the table, the appliance cannot 

be installed.  

Switch off the appliance, disconnect the gauge and close 
the seal screw  and contact the gas company to test main 

gas supply pressure. 

A pressure adjuster may have to be fitted upstream of 
the appliance. 

REPLACING MAIN BURNER NOZZLE 

• 

Lift up the grid above the hob and lift up the black covers and flame separators to check that the nozzles are 
screwed down correctly onto the holders.  

• 

Unscrew the nozzles and replace them with those required for the selected gas as specified on the rating 
plate The nozzles are marked in hundredths of a millimetre.

After converting or adapting for the gas, the plate specifying the type of nozzles used MUST be affixed above the 

rating plate. 

1.5    

Connecting to a different type of gas

1.     INSTALLATION

EN

Summary of Contents for 131.7433

Page 1: ...TENANCE MA NUAL FOR GAS COOKING TOPS LIVRET D INSTRUCTIONS POUR L UTILISA TION ET L ENTRETIEN DE L ENSEMBLE POUR PLANS DE CUISSO GEBRAUCHS UND WARTUNGSANLEI TUNG FÜR GASHERDE MANUAL DE INSTRUCCIONES PARA EL USO Y EL MANTENIMIENTO PARA HOR NALLAS GAS REV 002 2012 IT FR EN ES DE 131 7433 131 7463 ...

Page 2: ...tion instructions 11 Check before installation 11 Checking thermal power 12 Checking gas pressure 12 1 INSTALLATION 16 1 1 Avertissements importants 16 1 2 Positionnement 16 1 3 Evacuation des produits de combustion 17 1 4 RACCORDEMENT DU GAZ 17 Prescriptions pour l installation 17 Controles a effectuer avant l installation 17 Controle de la puissance ther mique 18 Controle de la pression du gaz 1...

Page 3: ...steel surfaces have to be kept properly clean Clean the parts in stainless steel daily with warm soapy water then rinse thoroughly and dry carefully On no account should the stainless steel be cleaned with steel wool pads brushes or scrapers in standard steel in that they could deposit fer rous particles which by oxidising cause rust spots Stainless steel wool can if necessary be used in the direc...

Page 4: ...em faults must be carried out only by qualified personnel in accordance with current rules and standards The gas systems wiring and premises in which the appliances are installed must comply with current rules and standards In particular the air supply for burner combustion must be 2m3 h per kW of installed power Accident prevention fire prevention and anti panic measures in businesses open to the...

Page 5: ...opcocks or gate valves whose internal diameter is not less than the above con necting pipe After connecting the pipe make sure that the joints and couplings have no leaks Use soapy water or a purpose designed foam product to detect leaks NEVER USE NAKED LIGHTS Gas supply pressure must be measured at the pressure point Ref P after removing the sealing screw Use a flexible pipe connect a gauge e g a...

Page 6: ...oam products DO NOT SEARCH FOR LEAKS WITH NAKED LIGHTS Before delivering the appliance to the user check that it operates correctly instruct the user on how to use it 2 OPERATING INSTRUCTIONS The appliance must be used only for the purpose for which it was designed Any other use is improper During operation supervise the appliance Before starting up the appliance for the first time unpack it Check...

Page 7: ...n Turn the knob to the minimum flame position to set a slower and more economical cooking procedure if required SWITCH OFF To put the appliance out switch the knob back to position closed At the end of the working day switch off the gas check valve upstream of the appliance At regular intervals at least once a year or more often in cases of frequent use service the appliance thoroughly This includ...

Page 8: ...0 19 kW 1 498 2 011 2 x 3 5 kW 2 x 6 kW LPG694F 21 3 kW 1 680 2 254 2 x 3 5 kW 2 x 6 kW 1 x 2 3 kW LPG694E 19 2 2 kW 1 498 2 011 2 x 3 5 kW 2 x 6 kW 1 x 2 2 kW EL LPG696F 31 2 kW 2 460 3 302 3 x 3 5 kW 3 x 6 kW 1 x 2 3 kW LPG794F 21 3 kW 1 680 2 254 2 x 3 5 kW 2 x 6 kW 1 x 2 3 kW LPG4920D 9 5 kW 0 749 1 005 1 x 3 5 kW 1 x 6 kW LPG6940D 19 kW 1 498 2 011 2 x 3 5 kW 2 x 6 kW LPG794E 19 2 2 kW 1 498 ...

Reviews: