![Bartscher 110555 Instructions For Installation, Use And Maintenance Manual Download Page 11](http://html.mh-extra.com/html/bartscher/110555/110555_instructions-for-installation-use-and-maintenance-manual_476642011.webp)
EN
page 29
INSTALLER SECTION
3. TECHNICAL DATA AND USEFUL INFORMATION ON PUMPS
3.1
Washing pump
When the dishwasher has not been used for some time, check that the washing pump turns
freely.
To do this, operate using a screwdriver in the special slot on the ventilating side of the motor
shaft.
In case of blocking, turn the main switch off and move the motor shaft, inserting the screwdri-
ver in the notch, turning it clockwise and anticlockwise.
3.2
Draining pump (optional)
When installing, pay particular attention to the positioning of the drain pipe (see image 7).
See paragraph
5.4
. for operation description.
image 8
3.3
Booster pump (optional)
After a period of inactivity of the machine, check if the rinse booster pump rotates freely.
To do that, use a screwdriver in the slot on the fan side of the motor shaft (see image 8) to
release.
MAX 0,8m
image 7
IMPORTANT
CAUTION: INCORRECT
POSITIONING OF THE TUBE.
CAUTION: CORRECT
POSITIONING OF THE TUBE
!
!
Summary of Contents for 110555