Reset WiFi 

 Press Reset WiFi when having trouble with the WiFi connection. The 

controller will reset the WiFi connection and attempt to reconnect to your currently 
saved connection.  

Manual WiFi Setup 

 

Used to manually set up a WiFi network that is hidden or 

otherwise not found when running WiFi Setup. Enter the network name under SSID and 

press “

Save

”. Under Password, enter the network password at press “

Save

”.

 

WiFi Status

 - Displays the currently connected network, WiFi signal strength, and cloud 

connection status. 

Headgrower Options 

 Used to set up the WeatherBoss for use with the Headgrower 

App and desktop version.  

Headgrower Via 

 Enable to allow the WeatherBoss to communicate to Headgrower.  

Headgrower Network 

 Select appropriate option for the WeatherBoss to communicate 

to Headgrower either as a Client, Hub, CIS, or Off. See your Headgrower manual for 
more information. 

Headgrower Channel 

 

Select the appropriate communication channel for the 

Headgrower app. See your Headgrower manual for more information. 

Headgrower ID 

 

Displays the HEadgrower ID for your controller. This is similar to your 

controllers serial number and cannot be changed.  

Humidity Cal 

 Used to enter the calibration code for the optional humidity sensor. 

Calibration codes can be found on the Humidity Calibration sheet sent with your 
humidity sensor. The humidity sensor does not come with the standard 

WeatherBoss

 

but is an additional option. Set to 0 if no sensor is connected.  

Light Sensor Source 

 

Used to activate or deactive the light sensor option. Select Off if 

no sensor is used or select Apogee SQ-110-SS if the light sensor is attached. After 
making th

e selection, press “

Save

”.

 

Reset Factory Defaults 

Resets all settings to factory defaults. Upon selection, you will be 

asked to confirm before the controller will be reset.

 

Calibrate Touch 

 

Used to re-

calibrate the touch screen if buttons aren’t working

 properly. 

Press the “

Calibrate Touch

” button and follow the onscreen instruction to re

-calibrate.

 

Factory Protected 

Factory protected is used by Bartlett to set controller and display modes. 

 

 

Summary of Contents for WeatherBoss

Page 1: ...8 28 20 1 WeatherBoss Operation Manual BARTLETT Instrument Co 1032 Ave H Fort Madison IA 52627 319 372 8366 www bartinst com...

Page 2: ...MENU SCREEN 5 SETTINGS 5 CONFIGURATION 5 SENSOR READINGS 7 RAIN SENSOR 7 WEATHER SENSOR 7 TEMPERATURE SENSOR 8 HUMIDITY SENSOR OPTIONAL 8 LIGHT PHOTO SENSOR OPTIONAL 9 MANUALLY ACTIVATE ALARM 9 BLOCK...

Page 3: ...e East but a low speed for winds from the West Alarm 2 could be the opposite having a high speed alarm set for wind from the West and low speed alarm from the East This alarm could be assigned to Vent...

Page 4: ...arm is active it will change to either be yellow Force or red Alarm Light Sensor Reading Displays the current light sensor reading in micro moles per second per meter squared Wind A2 Reading Displays...

Page 5: ...the Headgrower cloud platform for remote monitoring and control of the WeatherBoss See the WiFi section for more information about firmware updates WiFi Set up Wi Fi for Firmware download and for rem...

Page 6: ...hannel for the Headgrower app See your Headgrower manual for more information Headgrower ID Displays the HEadgrower ID for your controller This is similar to your controllers serial number and cannot...

Page 7: ...rection if a standard anemometer is being used High Activation Speed If the wind speed is greater than the High Activation Speed the alarm will activate When the alarm activates the environmental cont...

Page 8: ...work provided with your humidity sensor needs to be entered into the WeatherBoss Go to Menu Configuration Humidity Cal and enter the 4 digit code provided and press Save If a humidity sensor is not be...

Page 9: ...larm The Force button may be pressed at any time to activate the output of the Weather Alarm this is a manual override feature The Weather Alarm will close any open vents to the first programmed posit...

Page 10: ...estore factory default settings The default settings are Activation Set Point 20 MPH Drop Out Set Point 15 MPH Activation Delay 4 Seconds Drop Out Delay 6 Seconds Units English Response Time 1 Wind Al...

Page 11: ...peed drops below 15 miles per hour for 6 seconds Activation Set Point 20 MPH Drop Out Set Point 15 MPH Activation Delay 4 Seconds Drop Out Delay 6 Seconds 1 Output Off Wind speed is below the activati...

Page 12: ...ays The WeatherBoss will close any open roof vents to the first programmed position when the when the wind speed exceeds 20 miles per hour The roof vents will return control of the roof vents to the e...

Page 13: ...on set point and the output has not been triggered 3 Output On Wind speed is above the activation set point output triggers immediately 4 Output On Wind speed is below the activation set point and the...

Reviews: