background image

8/28/20 

Menu Screen 

By pressing the Menu button 

 indicated by 3 bars in the top left corner - on the Home Screen, 

you’ll

 be taken to the Menu Screen. The Menu Screen is a list of various options from controller info, 

WiFi settings, and more. For more information on each component of the Menu, see the descriptions 
below: 
 

Settings 

 
Set Clock 

Select to set the 

WeatherBoss

 clock. It is in military time. For Example:  3PM is 

entered as 15:00, 12AM is entered as 0:00, and 10AM is entered as 10:00. The clock can also be 
changed from the main screen by pressing Time. 

Set Date 

 Select to set the Day, Month, and Year in the controller. 

Temperature/Speed Units 

 Used to change the temperature & speed scale for the 

controller. Options are Fahrenheit/MPH or Celsius/KPH.  

 

Configuration 

 

 

Controller Info

 

Firmware Version

Serial Number

 and 

Mac address

 for the controller 

are shown here. This information may be required if you need any technical support. 
Additionally, it is used in conjunction with the Headgrower cloud platform for remote 
monitoring and control of the WeatherBoss. See the WiFi section for more information about 
firmware updates. 

WiFi

 

 

Set up Wi-Fi for Firmware download and for remote control and monitoring from the 

Headgrower cloud platform (Requires subscription). 

Enable Wi-Fi 

 Enable or disable the Wi-Fi feature. 

Disable 

turns Wi-Fi capabilities off at 

all times. 

Enabled 

turns the Wi-Fi on any time it is within range of a setup Wi-Fi 

connection. 

Wi-Fi Setup 

 To set up Wi-Fi for the 

WeatherBoss

, press “

Wi-Fi Setup

” and the 

controller will scan for nearby networks. Select your desired network and enter the 

password (if required) and press “

Save

”.

 

***For security reasons, we highly recommend that the user place all controllers into 
a separate logical network or VLAN, separate from other networks, routers, and 
hardware.

 

Update Firmware 

 If your controller is connected to the internet through the WiFi 

module, by pressing Update Firmware, the controller will connect to 

www.bartinst.com

 

to see if any updates are available. Once it has found the firmware, you have the option 
to update your controller. Updating firmware will 

NOT

 affect the 

controller’s

 programs. 

Summary of Contents for WeatherBoss

Page 1: ...8 28 20 1 WeatherBoss Operation Manual BARTLETT Instrument Co 1032 Ave H Fort Madison IA 52627 319 372 8366 www bartinst com...

Page 2: ...MENU SCREEN 5 SETTINGS 5 CONFIGURATION 5 SENSOR READINGS 7 RAIN SENSOR 7 WEATHER SENSOR 7 TEMPERATURE SENSOR 8 HUMIDITY SENSOR OPTIONAL 8 LIGHT PHOTO SENSOR OPTIONAL 9 MANUALLY ACTIVATE ALARM 9 BLOCK...

Page 3: ...e East but a low speed for winds from the West Alarm 2 could be the opposite having a high speed alarm set for wind from the West and low speed alarm from the East This alarm could be assigned to Vent...

Page 4: ...arm is active it will change to either be yellow Force or red Alarm Light Sensor Reading Displays the current light sensor reading in micro moles per second per meter squared Wind A2 Reading Displays...

Page 5: ...the Headgrower cloud platform for remote monitoring and control of the WeatherBoss See the WiFi section for more information about firmware updates WiFi Set up Wi Fi for Firmware download and for rem...

Page 6: ...hannel for the Headgrower app See your Headgrower manual for more information Headgrower ID Displays the HEadgrower ID for your controller This is similar to your controllers serial number and cannot...

Page 7: ...rection if a standard anemometer is being used High Activation Speed If the wind speed is greater than the High Activation Speed the alarm will activate When the alarm activates the environmental cont...

Page 8: ...work provided with your humidity sensor needs to be entered into the WeatherBoss Go to Menu Configuration Humidity Cal and enter the 4 digit code provided and press Save If a humidity sensor is not be...

Page 9: ...larm The Force button may be pressed at any time to activate the output of the Weather Alarm this is a manual override feature The Weather Alarm will close any open vents to the first programmed posit...

Page 10: ...estore factory default settings The default settings are Activation Set Point 20 MPH Drop Out Set Point 15 MPH Activation Delay 4 Seconds Drop Out Delay 6 Seconds Units English Response Time 1 Wind Al...

Page 11: ...peed drops below 15 miles per hour for 6 seconds Activation Set Point 20 MPH Drop Out Set Point 15 MPH Activation Delay 4 Seconds Drop Out Delay 6 Seconds 1 Output Off Wind speed is below the activati...

Page 12: ...ays The WeatherBoss will close any open roof vents to the first programmed position when the when the wind speed exceeds 20 miles per hour The roof vents will return control of the roof vents to the e...

Page 13: ...on set point and the output has not been triggered 3 Output On Wind speed is above the activation set point output triggers immediately 4 Output On Wind speed is below the activation set point and the...

Reviews: