Technical Data
7" Industry Tablet
- Lumen X7
Type B7-A23.-2…/……..
EN 12/61
Subject to technical changes.
03/2016
X - labelling (special conditions of use for secure operation within the potentially
explosive atmosphere)
The ambient temperature range is -10 °C to +50 °C.*
The device must be protected from impact with high impact energy, from intense
UV-irradiation, and strongly charge generating processes.
It is not allowed to use connectors inside the potentially explosive atmosphere.*
It is not allowed to remove, change and/or charge the battery inside the potentially
explosive atmosphere.*
*See individual chapter on the points in the User Manual.
3.2
Applicable standards
Explosion protection
EN 60079-0:2012 + A11:2013
Explosive atmospheres - Part 0: Equipment -
General requirements
EN 60079-11:2012
Explosive atmospheres - Part 11: Equipment
protection by intrinsic safety "i"
IEC 60079-0:2011
Explosive atmospheres - Part 0: Equipment -
General requirements
IEC 60079-11:2011
Explosive atmospheres - Part 11: Equipment
protection by intrinsic safety "i"
ANSI/ISA 12.12.01
ANSI/ISA-12.12.01-2013 Nonincendive Electrical
Equipment for Use in Class I and II, Division 2
and Class III, Divisions 1 and 2 Hazardous
(Classified) Locations
CAN/CSA C22.2 No. 213-M1987 Non-Incendive Electrical Equipment for Use in
Class I, Division 2 Hazardous Locations
Electrical safety
IEC 60950-1 (ed.2); am1
CSA22.2 No. 60950-1-07
Information technology equipment - Safety -
Part 1: General requirements
Radio specification - WLAN / Bluetooth
EN 300 328 V1.8.1: 2012
Electromagnetic compatibility and radio spectrum
matters (ERM) – wideband transmission systems
– data transmission equipment operating in the
2.4 GHz ISM band and using wideband
modulation techniques
Summary of Contents for Lumen X7 B7-A23.-2 SERIES
Page 2: ......
Page 6: ...empty...