7
Operation
7.1
Inspection to be conducted prior to use
DANGER
Spark formation caused by the connection cable or the battery falling out!
Ensure that the safety lock has been correctly closed prior to use in the potentially
explosive atmosphere.
Check the following points before operating the device:
Final inspection of BCS3608
ex
-NI / BCS3608
ex
-IS (corded)
Check points
Scan window free from damage, e.g. scratches
Enclosure free from damage, e.g. crack or break
Temperature in the area in which the hand-held scanner is used corresponds to the
specified temperature range
Cables are not damaged
Cables have been certified
Cable on the hand-held scanner is securely engaged and locked
Cables on the supply module are securely engaged, locked or screwed tight
Final inspection of BCS3678
ex
-NI / BCS3678
ex
-IS (Bluetooth)
Check points
Scan window free from damage, e.g. scratches
Enclosure free from damage, e.g. crack or break
Temperature in the area in which the hand-held scanner is used corresponds to the
specified temperature range
If cables are present: cables are not damaged
If cables are present: cables have been certified
Battery is certified for the corresponding hand-held scanner
Battery compartment cover has been correctly locked
Cables on the supply module are securely engaged, locked or screwed tight