Scan in the pairing barcode on the supply module Ex i BT.
The barcode can be found on the cover.
The barcode for pairing can be created at any time using the Zebra 123Scan utility. Use the
MAC address of the Bluetooth module in the supply module Ex i BT for this.
Programming/setting via the Zebra 123 Scan Utility is not supported via the supply module.
A programming cable is required.
The hand-held scanner is paired to the supply module Ex i BT via Bluetooth. The supply module
Ex i BT transmits serial data on the output side. You can find the set factory defaults below.
Default settings of the Bluetooth module in the supply
module Ex i BT
RS-232 host parameters
Baud rate:
9600 baud
Parity:
None
Stop bits:
1-bit
Data bits:
8-bit
Hardware handshaking: None
Software handshaking: None
Further customized settings can be performed with the help of the Zebra Product Reference
Guide or the Zebra 123Scan utility.