BCS36x8
ex
Series
Connection example
Type 17-A1S4-*HP* and B7-A2S4-****
Page 74 of 78
Subject to technical changes.
05/2020
14.1.4
Testing communication/data transmission
The communication/data transmission on the Ex-HMI device can be tested with the help of a terminal
program or a software keyboard wedge.
A software wedge or other application must be installed on the Ex-HMI device for data
transmission when using a supply module Ex i BT.
The software wedge or other application is used to convert the incoming data to a keyboard
entry and to enter the data into the field currently active on the Ex-HMI device.
Terminal program
The test with a terminal program described below was conducted with the H-Term application.
Alternatively any other terminal program that supports serial communication may be used.
Testing communication/data transmission
Open terminal program
Select serial interface to which the BCS3608
ex
is connected (COM6 in the example).
Can be checked in the device manager.
Perform settings in the terminal program and press ‘Connect’.
Read barcode with scanner and check in the terminal program that the data are displayed.
Data transmission is OK if the barcode data is displayed in the “Received Data” window.
If not, check connection and programming.