BCS36x8
ex
Series
Connection example
Type 17-A1S4-*HP* and B7-A2S4-****
Subject to technical changes.
05/2020
Page 73 of 78
Scan in the pairing barcode on the supply module Ex i BT.
The barcode can be found on the cover.
The barcode for pairing can be created at any time using the Zebra 123Scan utility. Use the
MAC address of the Bluetooth module in the supply module Ex i BT for this.
Programming/setting via the Zebra 123 Scan Utility is not supported via the supply
module Ex i BT.
A programming cable is required.
The hand-held scanner is paired to the supply module Ex i BT via Bluetooth. The supply module
Ex i BT transmits serial data on the output side. The connected USB interface is detected by the
host PC as a virtual serial (COM) interface.
Default settings of the Bluetooth module in the supply
module Ex i BT
RS-232 host parameters
Baud rate:
9600 baud
Parity:
None
Stop bits:
1-bit
Data bits:
8-bit
Hardware handshaking: None
Software handshaking: None
Further customized settings can be performed with the help of the Zebra Product Reference
Guide or the Zebra 123Scan utility.