BCS36x8
ex
Series
Connection example
Type 17-A1S4-*HP* and B7-A2S4-****
Subject to technical changes.
05/2020
Page 23 of 78
Universal supply module - terminal assignment
Terminal
Mains connection / RS232 interface
X1
L (230V)
L = 100 V
AC
to 240 V
AC
±10% / 50/60 Hz
X2
N (230V)
N = Neutral conductor
X3
+ (24V)
24 V
DC
+ ±10% / 0,4A
X4
- (24V)
24 V
DC
– ±10% / 0,4A
X5 1 TxD
X6 2 RxD
X7 3 RTS
X8 4 CTS
X9 GND GND
X10 SHIELD –
Universal supply module – 1
st
generation with DIP switch
Setting
DIP switch
Interface
S1
S2
S3
S4
RS232 0 0 0 1
The interface is set using DIP switches S1, S2 and S3.
DIP switch 4 is used to select whether the universal supply module is suitable for the wired or
Bluetooth hand-held scanner.
S4: 0 = wired / 1 = Bluetooth
Universal supply module – 2
nd
generation without DIP switch
Scan the programming code for the RS232 serial interface.
The universal supply module (USM) is already preset on the hardware side to the Bluetooth
scanner version.