background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date: 27.03.2015

 

User Manual 

Bluetooth Handheld Scanner  

iSCAN201 

Summary of Contents for iSCAN201

Page 1: ...Date 27 03 2015 User Manual Bluetooth Handheld Scanner iSCAN201 ...

Page 2: ...sembly 2 10 3 3 Cable range in system assembly 1 11 3 4 Cable range in system assembly 2 11 4 Step by step guide on installation and operation 12 4 1 Preparation handheld iSCAN201 scanner for system assembly 1 and 2 12 4 2 Using the base charging station for system assembly 1 hazardous areas 14 4 3 Using the base charging station for system assembly 2 non hazardous areas 15 4 4 Pin assignment powe...

Page 3: ...n Warnings are highlighted by a special symbol and a different font colour Danger Non compliance may result in life threatening situations This warning must be heeded Warning This type of warning concerns dangerous situations that may result in minor injuries Info Important and helpful notes and information ...

Page 4: ...must ensure that they have the most up to date version of the operating instructions To make sure this is the case please check Extronics website www extronics com or contact one of the company s staff The drawings contained in these operating instructions are for illustration purposes only and may differ somewhat from the actual design No changes may be made to the device that were not intended o...

Page 5: ...e used explosion protection is no longer guaranteed Ensure safe handling with firm footing and sufficient room for movement If the enclosure is in any way damaged the device must be removed from the hazardous area immediately In accordance with IEC 60079 19 and IEC 60079 17 operators of electrical installation in hazardous areas are obliged to have them serviced by qualified electricians Do not in...

Page 6: ...d looking directly into the light Brief exposure to a class 2 laser is deemed not dangerous Maintenance Provided the device is operated and assembled according to instructions and the ambient requirements are being met continuous maintenance is not necessary Servicing Operators of electric equipment in hazardous areas are obliged to have them serviced by qualified electricians IEC 60079 19 and IEC...

Page 7: ...2 2 Explosion protection II 2G Ex ib IIC T4 II 2G Ex ib IIC T4 Gb II 2D Ex ib IIIC T135 C II 2D Ex ib IIIC T135 C Db Protection category IP65 2 3 Scanner technical data Nominal values Light source Visible red light 630nm Ambient temperature 20 C to 50 C Test certificate IBExU 12 ATEX 1162 Bluetooth V2 1 EDR Weight 260g inc batteries Bluetooth range up to 30 m ...

Page 8: ...e charging station may be operated in hazardous areas Its purpose is to receive data captured by the associated handheld scanner 1D bar codes or 2D stacked codes via Bluetooth Nominal values of the hazardous base charging station maximum input voltage Ui 4 9 V ISCAN201CAB 5 6 9 10 5 6 V ISCANCAB7 8 maximum input current li 490 mA maximum input power Pi 1 25 W maximum internal inductance Li negligi...

Page 9: ... supply ISCANPS depending on voltage and interface iSCAN201EXB Explosion protected base charging station iSCAN201B Non explosion protected base charging station iSCAN201BNOBT Non explosion protected charging station without Bluetooth 2 6 Serial numbers Serial key year of manufacture serial number 2 numbers 4 numbers Example 130001 2 7 Application The scanner is a handheld device Its purpose is the...

Page 10: ...y and a connection cable between the power supply and a PC Required connection cable to a PC USB 0 2 2 5 mm 4 wire or RS232 0 2 2 5 mm 3 wire The Bluetooth handheld scanner the base charging station and the power supply can be connected and operated in the hazardous area For safe installation of the power supply please refer to the manual issued by SICK AG www SICK com The warnings and notes of ca...

Page 11: ...cription The Bluetooth handheld iSCAN201 scanner can also be used separately in the hazardous area The base charging station is then operated in the non hazardous area Use an RS232 cable or a USB cable to connect the station directly to a power supply and a PC The warnings and notes of caution contained in these operating instructions and in the manual issued by SICK AG www SICK com must be adhere...

Page 12: ...ase charging station 1 8 or 3 8m optional with 4 5m or 6m extension iSCANPS Up to 20m Host USB iSCAN201 Base charging station 1 8 or 3 8 m iSCANPS Up to 5m Host RS232 iSCAN201 Non hazardous base charging station 1 8 or 3 8m optional with 4 5m or 6m extension Host USB iSCAN201 Non hazardous base charging station 1 8 or 3 8 m Host ...

Page 13: ...t in the termination of the operating permit The battery compartment is located at the bottom of thescanner Loosen the screw to remove the lid Open the battery compartment After the screw has been loosened the removal of the lid requires a certain amount of force An iSCAN201BATT is required to operate the scanner Only use this battery for the Bluetooth Scanner Before placing the battery inside the...

Page 14: ...The end of the removal strap must be protrude from the opening If the battery has been correctly inserted and connected to the contacts this will be indicated by an acoustic and a visible signal Close the compartment Check that the screw has been tightened properly ...

Page 15: ...in the opening at the bottom of the base charging station If the cable has been inserted fully you can hear a click Check if the cable fits firmly Insert the plug of the connection cable into the power supply s plug connector Ensure that the connection is fully secured with the screw cap after the plug has been inserted Place the iSCAN201 handheld scanner onto the charging station Insert the lower...

Page 16: ...tion in a non hazardous area the connection cable for the power supply and the PC is inserted in the opening at the bottom of the base charging station Use ISCAN201CAB1 or 2 as a RS232 cable and ISCAN201CAB 3 or 4 as a USB cable If the cable has been inserted fully you can hear a click Check that the cable fits firmly Place the ISCAN201 handheld scanner onto the charging station Insert the lower p...

Page 17: ...ce in a hazardous area you have to ensure that the enclosure has been closed fully and all screws have been tightened Any changes to the terminal assignment may only be carried out by trained staff Connection of base charging station to the RS232 power supply with plug connection Base connection cable RS232 Typ ISCAN201CAB5 or 6 Power Supply Typ ISCANPS1 or 3 Pin assignment connection coupling Pre...

Page 18: ... sleeves To fully operate the handheld ISCAN201 scanner you will require the programming information contained in the manual published by SICK AG www SICK com Base charging station ISCAN201 RS232 RJ 45 Pin assignment Wire colours Definition Assignment 6 White TXD X9 X10 X11 7 Brown GND X12 3 Yellow UB X13 intrinsically safe connection box of the ISCANPS1 or 3 power supply after removal of the wire...

Page 19: ...evice in a hazardous area you have to ensure that the enclosure has been closed fully and all screws have been tightened Any changes to the terminal assignment may only be carried out by trained staff Connection base charging station to the USB power supply with plug connection Base connection cable USB Typ ISCAN201CAB9 or 10 Power Supply Typ ISCANPS2 or 4 Pin assignment connection coupling Pre as...

Page 20: ... cable end sleeves Base charging station ISCAN201 USB RJ 45 Pin assignment Wire colours Definition Assignment 2 Green D 2SL X9 10 White D 2SL X10 X11 7 Black GND X12 3 Brown UB X13 intrinsically safe connection box of the ISCANPS2 or 4 power supply after removal of the wires of the plug connection To fully operate the handheld ISCAN201 scanner you will require the programming information contained...

Page 21: ...Operating Instructions_iSCAN201_001 20 5 1 EC type examination certificate ISCAN201 and ISCAN201 base charging station 5 Attachment ...

Page 22: ...Operating Instructions_iSCAN201_001 21 ...

Page 23: ...Operating Instructions_iSCAN201_001 22 5 2 EC type examination certificate Power supply ISCANPS ...

Page 24: ...Operating Instructions_iSCAN201_001 23 ...

Page 25: ...Operating Instructions_iSCAN201_001 24 ...

Page 26: ...Operating Instructions_iSCAN201_001 25 ...

Page 27: ...Operating Instructions_iSCAN201_001 26 Extronics Limited 1 Dalton Way Midpoint 18 Middlewich Cheshire UK Tel 44 0 845 277 5000 Fax 44 0 845 277 4000 info extronics com 6 Contact ...

Reviews: