background image

Installation Instruction 

(Translation) 

RFID UHF Add-On Module 

Type B7-A2Z0-0032 

 

Technical data subject to change. 

08/2016 

EN   1/11

 

 

 

Basic Information

 

Read carefully before putting the devices into operation.

 

The Installation Instruction is a fixed part of the product. It must be kept in the direct 

vicinity of the device and the installation, operating and service staff must have access 

to it at all times. 

More detailed instructions of the use can be found at 

www.bartec.de

 as well as t

he current versions 

of the datasheets, user manual, certificates and EU declaration conformity or may be requested 

directly from BARTEC GmbH.

 

Knowledge of the safety and warning information and the strict compliance with it is essential for 

safety installation and use. Injuries and material damage can be avoided by circumspect handling 

and systematically following the instructions.  
The BARTEC company reserves the right to carry out technical changes at any time.  

Maintenance and Repairs 

The pertinent erection and operating provisions for electrical systems 

must be observed! Repairs to explosion-protected devices may only be performed  by authorised 

personnel with original spare parts and according to the state of the art. The applicable provisions 

must be observed in this respect. 

Inspections 

According to EN/IEC 60079-17 and EN/IEC 60079-19, the operator of electrical 

systems in potentially explosive atmospheres is obliged to have these inspected by an electrician to 

ensure correct condition. 

Warranty 

If non-specified components are used, the explosion protection will no longer be 

guaranteed. In the case of externally procured parts, it  is not guaranteed that these have been 

designed and manufactured in accordance with their load and requisite safety. 

Disposal 

As professional electrical devices, our devices are intended exclusively for commercial 

use, so-called B2B devices, in accordance  with the WEEE Directive. Observe the national waste 

disposal regulations when disposing of the devices. All products purchased from us can be returned 

to us by our customers for disposal. The sender shall bear the costs of postage and packaging. 

 

Summary of Contents for B7-A2Z0-0032

Page 1: ...ATEX IECEx Zone 2 22 UL Class I Division 2 RFID UHF Add On Modul Type B7 A2Z0 0032 Installation Instruction...

Page 2: ......

Page 3: ...Status 8 August 2016 Reservation Technical data subject to change without notice Changes errors and misprints may not be used as a basis for any claim for damages Content Pages English 1 11 BARTEC Gmb...

Page 4: ...Repairs The pertinent erection and operating provisions for electrical systems must be observed Repairs to explosion protected devices may only be performed by authorised personnel with original spar...

Page 5: ...d The generally applicable statutory regulations and other binding guidelines on occupational health and safety on accident prevention and on environmental protection must be complied with Danger Warn...

Page 6: ...4 IIA when using hand strap type 03 9849 0130 IECEx EPS 15 0010X UL Division 2 Class I Div 2 Groups A B C D T4 A UL File E321557 Special conditions for safe use Maximum ambient temperature range 20 C...

Page 7: ...approx 150 cm Maximum transmission power The transmission power can be adjusted separately for reading and writing Adjustable from 0 dBm to 30 dBm in 0 5 dBm steps Accuracy 1 dBm Energy management pow...

Page 8: ...n instruction RFID UHF Add On Module DANGER The extension interface of the Agile X industrial tablet PCs must always be sealed in a potentially explosive atmosphere There is a risk of explosion Only r...

Page 9: ...they have been tested and certificated by BARTEC Avoid data losses Do not just switch the Agile X using the ON OFF switch 1 Shut the Agile X down using the operating system 2 Place the Agile X on the...

Page 10: ...d assembly 9 Switch the Agile X on using the ON OFF button Optional Attach hand strap Material No 03 9849 0130 10 Loosen the top screw M3x7 that holds the RFID UHF Add On Module in place 11 Place the...

Page 11: ...on the option Device ON OFF 4 Select Ext Module to active the extension interface orange ON White OFF 5 UHF power set to ON In up to date versions of the operating system the driver has already been...

Page 12: ...6Exx device is shown in the device manager under Other devices after assembly of the RFID UHF Add On Module 2 Download the driver at USB to RFID UHF driver http automation bartec de If no new device i...

Page 13: ...a subject to change 08 2016 EN 10 11 3 In the new Update Driver Software window click on the Browse my computer for driver software option 4 Click on the Browser button and manually switch to the driv...

Page 14: ...At the end of the installation Windows reports that the driver has been successfully installed Close the Update Driver Software window using the Close button 8 After installing the driver the RFID UH...

Page 15: ......

Page 16: ...0 7N0002 08 2016 Automation 403699 Your partner for safety technology Challenge us BARTEC GmbH Germany Phone 49 7931 597 0 Fax 49 7931 597 119 Max Eyth Str 16 97980 Bad Mergentheim info bartec de www...

Reviews: