Maintenance and fault clearance
Death or serious injury through damaged
flameproof encapsulation.
Replace defective parts in the flameproof
encapsulation with original parts immedi-
ately.
Risk of serious injury due to incorrect
proceedings.
Only authorized qualified personnel may
do any of the work relating to maintenance
and fault clearance.
IEC/EN 60079-17 must be observed. It is
recommended to formulate a maintenance
plan according to this standard.
Maintenance work
The operator of the potentiometer must keep it
in good condition, operate it correctly, monitor it
and clean it regularly.
Visually inspect the threaded gap.
Visually inspect the flameproof encapsu-
lation for damage.
Note
In the course of maintenance particular atten-
tion must be paid to checking that the parts
essential for the type of protection and proper
functioning are in good condition.
Fault clearance
The potentiometer is defective if the flameproof
encapsulation is damaged and/or if one of the
components does not function any longer
In this case:
Replace defective parts in the flameproof
encapsulation with original parts immedi-
ately.
Replace or repair the defective compo-
nents with original parts.
Note
Follow the components mounting instruc-
tions/operating instructions to replace or repair
the components.
Accessories, spare parts
See BARTEC catalogue.
Disposal
The potentiometer components contain metal
and plastic parts.
The statutory requirements for disposing of
electronic scrap must be observed therefore
(e.g. disposal by an approved disposal compa-
ny).
Service address
BARTEC GmbH
Max-Eyth-Straße 16
97980 Bad Mergentheim
Germany
Tel.:
+49 7931 597-0
Fax:
+49 7931 597-119
Dimensions
Selection chart
Order number
Temperature
class
Max. power
loss
a
in mm (in)
b
in mm (in)
c
in mm (in)
d
in mm (in)
e
Overall length f
in mm (in)
07-6622-.111/…. T6
2.5
W
Ø 30 (1.2)
55 (2.2)
Ø 6 (0.2)
11 (0.4)
M12x1.5
66 (2.6)
07-6622-.112/…. T6
1.2
W
45 (1.8)
55 (2.2)
07-6622-.113/…. T6
2
W
07-6623-.111/….
T5
3 W
55 (2.2)
66 (2.6)
07-6624-.111/….
T6
5 W
Ø 45 (1.8)
90 (3.5)
101 (4)
07-6624-.102/….
T6
2 W
Ø 38 (1.5)
50 (2)
Ø 6.35 (0.3)
8 (0.3)
3/8-32
UNEF
61 (2.4)
07-6625-.111/….
T5
6 W
Ø 45 (1.8)
90 (3.5)
Ø 6 (0.2)
11 (0.4)
M12x1.5
101 (4)
07-6626-.111/…. T6
7
W
Ø 60 (2.4)
87 (3.4)
98 (3.9)
07-6627-.111/…. T5
8
W