Operational Instruction 

(Translation)

 

  Potentiometer 

Type 07-662.-…./…. 

 

 

BARTEC

 GmbH  Max-Eyth-Straße 16  

97980 Bad Mergentheim 

Germany 

Tel.:  +49 7931 597-0 

Fax:  +49 7931 597-119 

[email protected] 

www.bartec.de 

Reservation  Technical data subject to change without notice. Changes, errors and 

misprints may not be used as a basis for any claim for damages. 

EN 2/4 

 

 

07-6620-7D0002/

A-0

2/

15-STVT-381059

 

Safety instructions 

The potentiometer may be used only within the
specified temperature class and the tempera-
ture range indicated for it (see type label).  
The potentiometer is not suitable for use in
zones 0/20.  
The potentiometer may be operated only if it is
clean and not damaged in any way. Dust 
deposits exceeding 5 mm (> 0.2 in) must be
removed. 
Utilization in areas other than those specified
and the opening or modification of the product
by anyone other than the manufacturer are not 
permitted and will exempt BARTEC from liabil-
ity for defects and any further liability. 
The generally applicable statutory rules and
other binding directives relating to workplace
safety, accident prevention and environmental
protection must be observed. 
When using electrical systems, the relevant
installation and operating conditions must be
observed. The specifications on the type label
must be adhered to. 
Observe the applicable laws and directives
when commissioning or restarting operation. 
Always follow the safety instructions on the
operating equipment. 
 

Marking 

Particularly important points in these instruc-
tions are marked with a symbol: 
 

 

DANGER indicates a hazardous situation
which, if not avoided, will result in death or 
serious injury. 

 

WARNING indicates a hazardous situation 
which, if not avoided, could result in death or 
serious injury. 

 

CAUTION indicates a hazardous situation
which, if not avoided, could result in minor or 
moderate injury.  

 

NOTICE is used to address practices not 
related to personal injury. 
 

 

Note 

Important instructions and information on
effective, economical and environmentally
compatible handling. 

 

 

Standards conformed to 

EN 60079-0:2012/IEC 60079-0 : 2011 
EN 60079-1:2007/IEC 60079-1 : 2007-04 
EN 60079-7:2007/IEC 60079-7 : 2006-07 
EN 60079-31:2009/IEC 60079-31 : 2008 

 

ABNT NBR IEC 60079-0 
ABNT NBR IEC 60079-1 
ABNT NBR IEC 60079-7 
ABNT NBR IEC 60079-31 

 

as well as 

 

EN 60204-1:2006/IEC 60204-1:2005, mod. 
EN 62208:2011/IEC 62208:2011 
EN 60445:2010/IEC 60445:2010 
EN 60529:1991 + A1:2000 + A2:2013/ 
IEC 60529:1989 + A1:1999 + A2:2013 
 

Transport, storage 

 

Damage to the potentiometer through incor-
rect transport or incorrect storage. 

 

Transport and storage is permissible in
original packaging only. 

 

Assembly / disassembly 

 

Risk of serious injury due to incorrect 
proceedings. 

 

Only authorized and qualified personnel 
may do any of the assembly, disassembly,
installation and commissioning work. 

 

Always disconnect the device from voltage
before assembly/disassembly. 

 
When assembling the device, take care that the
distances between the outside edge of the
flame-proof gap and the fixed obstacles that
are not part of the device are for: 
 

Gas/vapour sub-group 

IIC IIB 
at least 40 mm 
(1.58 in) 

at least 30 mm 
(1.18 in) 

 
The potentiometer must be fitted into an enclo-
sure that conforms to the requirements of a
type of protection recognized as being in ac-
cordance with IEC/EN 60079-0. 
When fitting into an enclosure with “Ex e” type
of protection the clearance and creepage
distances under IEC/EN 60079-7 Section 4.3, 
Section 4.4 and Table 1 must be observed. 

 

Installation 

 

Death or serious injury due to improper use. 

 

Extensions or modifications to the potenti-
ometer are only permissible if the manufac-
turer’s approval is obtained first. 

 

The IEC/EN60079-14 must be observed. 

 
Check at the installation: 

 

When connecting cables and conductors 
to operating equipment with the “Ex e” 
type of protection, use Ex-certified cable 
entries that are suitable for the respective 
types of cables and conductors. They 
must conform to the “Ex e” type of protec-
tion and have a suitable sealing element 
uphold the device’s protection class. 

 

Connect metallic cable entries to the 
earthing system. 

 

Seal unused cable entry holes with Ex-
certified stopping plugs.  

 

When connecting directly to the flame-
proof enclosure, use Ex-certified entries 
that are suitable for the enclosure capaci-
ty, the gas sub-group and the conductor. 

 
Take care when connecting conductors: 

 

Always use suitable crimping tools when 
crimping the wire-end ferrules to ensure a 
consistent quality of pressing each time.  

 

Take care not to damage the individual 
wires. 

 

Tighten all terminal points securely (in-
cluding those not in use). 

 

Commissioning 

Before commissioning, check that: 

 

The device has been installed in compli-
ance with regulations. 

 

The device is not damaged. 

 

The connection has been established 
properly. 

 

All screws have been tightened securely. 

 

The device functions perfectly. 

 

Operation 

 

Death or serious injury through improper 
use. 

 

The potentiometer may be operated only 
within the technical limits that apply to it 
(see page 1). 

 

 