−29−
8-4 Fuel gauge
It indicates current fuel level. If the fuel
gauge approaches E(Empty), supply fuel
(diesel) immediately.
* The capacity of the fuel tank is
approximately 47 Liters.
E
F
14
F U E L
1 2
34
Danger
Don't oversupply the fuel. It may cause the fire, if the fuel overflow
from the fuel tank. Use diesel oil only. Be sure not to use gasoline.
8-5 Charge lamp
The lamp turns on when the ignition switch
is in the "ON" position. After the engine
starts, and the light will turn off if it charges
normal. When the lamp is turned on during
operation, stop the engine immediately and
inspect, do maintenance and repair.
Charge lamp
Charge
Engine oil
pressure
Glow
8-6 Thermo-start lamp (glow lamp)
Refer to 7-3 "Starting and stopping the
engine".
Charge
Thermo-start lamp
(Glow lamp)
Glow
Engine oil
pressure
8-7 Oil pressure lamp (engine oil pressure lamp)
The lamp turns on when the ignition switch
is in the "ON" position.
After the engine starts, the light will be
turned off, if the oil begins to circulate and it
becomes the normal pressure.
When the lamp i s turned on dur ing
operation, stop the engine immediately and
carry out the maintenance and repair.
Engine oil pressure lamp
Charge
Engine oil
pressure
Glow