Table 10
: common parameters, highlighted in grey if read-only even with “Administrator” level of access.
Idx Parameter
D
ec
. d
ig
its
M.U.
Min
Value
Max
Value
Default
Value
0
Cycle time
(if changed, the new value will be active at the next system
start up)
1
sec
0.5
10.0
2.0
1
% SP end Soft Start - start Auto Tuning
0
%
1
100
25
2
SP1/SP2 selection
0
0=SP1
1=SP2
0
4
Baud Rate
-
38400
38400
38400
5
Synchronous heating tolerance
0
°C
0=off
100
10
6
Band outside of that fuoc value is idx 7
(if the ramp is active)
1
°C
0
9999
30.0
7
Fuoc value outside of band (referring to parameter idx=6) 1
-
0.1
10.0
1.0
8
K_TAU for Auto Tuning calculation
1
-
0.1
100.0
20.0
9
K_FPB for Auto Tuning calculation
1
-
0.1
100.0
4.0
10 Cpb, corrective factor for proportional band
1
-
0.1
100.0
1.5
11
Drying time
0
sec
0
999
900
12 Drying voltage
0
Volt
60
190
160
13 Proportional Band under Auto Tuning temperature
1
°C
0
199.9
1.0
14 Integral time under Auto Tuning temperature
0
sec
0
999
0
15 Derivative time under Auto Tuning temperature
0
sec
0
999
0
16 Temperature threshold to abort Soft Start
0
°C
0
999
80
17 Digital filter for displayed temperature
1
°C
0.0
10.0
2.0
18 OUTPUT 1 (enabling signal) logical level
-
-
0:open=OK
1:close=OK
1
19 OUTPUT 2 (alarm signal) logical level
0:open=Fail
2:open=Fail
1:close=Fail
3:close=Fail
3
20 WAIT Output enabled (OUTPUT 3)
0: not active
1:active
1
21 Logical level OUTPUT 4 (used for fans)
22 INPUT 1 (switch to SP2) logical level
0:open=SP2
1:close=SP2
1
23 INPUT 2 (switch to “OFF” all the zones) logical level
0:open=OFF
1:close=OFF
1
24 Logical level INPUT 3 (not used)
25 Hold band for wait after end of Auto Tuning
0
°C
0
100
15
26 Validate band of temperature around SP (LEAKAGE ALARM) 1
°C
0
999.9
5.0
27 Delay after Set Point is reached for power calculation
(LEAKAGE ALARM)
0
sec
30
7200
900
28 Time for average power calculation (LEAKAGE ALARM)
0
sec
30
7200
300
29 Relative power % increasing to get the LEAKAGE ALARM
0
%
0
100
50
30 Digital output delay
0
min
0
1000
1
31 Set Point change band for LEAKAGE ALARM power
recalculation
0
°C
0
100
15