46
13
Auto Tuning enabled
(The tuning of PID parameters will be performed if
selected at the heating start)
-
0=Off,1=On
On
14
Pb (Proportional band, calculated during TUNE
phase)
1
°C
0
199.9
16.4
15
Int (Integral Time, calculated during TUNE phase)
0
sec
0
999
16
16
Der (Derivative time, calculated during TUNE phase) 0
sec
0
999
3
17
Integral preload
0
%
0
100
0
18
Fuzzy overshoot control (calculated during TUNE
phase)
1
-
0.1
10.0
0.4
19
SP MIN (Set Point minimum value)
0
°C
0
SPMAX
50
20
SP MAX (Set Point maximum value)
0
°C
SPMIN
999
400
21
Ramp up (GR+)
(working Set Point increasing ramp)
1
°C/min
0
99.9, 100.0=Max 20.0
22
Ramp Dn (GR-)
(working Set Point decreasing ramp)
1
°C/min
0
99.9, 100.0=Max 100.0
23
MaxPowRatio (RNP)
0
%
0
100
100
24
Time duration of the Soft Start
0
min
0
200
4
28
Average power (according to common parameter
Idx 35)
2
%
0
10000
Read-only
29
Loop break alarm Time
0
sec
0
500
0
30
Loop break alarm step softstart
0
°C
0
100
0
31
Loop break alarm
0
°C
0
100
5
40
Saved A0 Auto Tuning
0
sec
--
Read-only
41
Saved A1 Auto Tuning
1
°C
--
Read-only