If you need to change only one parameter value, input the desired value directly in the page
of Figure 58, selecting the field that you want to change.
Page of Figure 63 shows that the process is in progress.
Figure 63
Table 9
: zone parameters, highlighted in grey if read-only even with “Administrator” level of access.
Idx Parameter
D
ec
. d
ig
it
s M.U.
Min
Value
Max
Value
Default
Value
0
SP1
0
°C
SPMIN
SPMAX
140
1
SP2
0
°C
SPMIN
SPMAX
70
2
BarGraph Delta +
(Tolerance band if T>SP)
0
°C
0
999
10
3
BarGraph Delta –
(Tolerance band if T<SP)
0
°C
0
999
10
4
AL1 threshold (over-temperature)
0
°C
0
999
400
6
Output power high limit during Soft Start
0
%
0
100
15
7
BOOST Delta
(SP icrease during BOOST phase)
0
°C
0
100
0
8
TC type and temperature measuring unit
-
0=J/°C, 1=K/°C, 2=J/°F, 3=K/°F 0
9
Security power
0
%
0=Off,1=On
Off
10
Measure offset
1
°C
-10.0
10.0
0
11
Hysteresis AL1
0
°C
0
5
12
Alarms enabled even if the zone status is OFF
-
0=Off,1=On
Off