Zone
It’s the number (from 1 to 6) of the selected zone on it’s power board (e.g. the 7
th
zone is the 1
st
of the 2
nd
board)
Channel
It’s the network where the power board is connected. Until 14 boards (84 zones),
there will be just one channel
Address
It’s the serial address of the power board, corresponding to the dipswitch “U43”
configuration
Fuse
It’s the identification label of the fuse, printed on the power board
Figure 30
is the “Working Set Point”: the ideal temperature at any time, based on the programmed
ramps of increasing and decreasing (zone parameters “Ramp up (GR+)” Idx 21 e “Ramp DN (GR-
)” Idx 22).
When the zone is in “SLAVE” mode, the active power will be the same of the set
(refer to paragraph 4.8).
The
è is the active power when the zone is in “MANUAL” mode
(refer to paragraph 4.6)
The
is the average value of the heating power %. The average calculation
time is the common parameter “Time for calculation of average power” Idx 35 (refer to
paragraph 6.14)
The
is the value of normal power % absorption of each
regulating zone. This value is stored when the operator reply “
Yes
” at the question “
Are the
moulded pieces OK?
” (refer to paragraph 4.9).
If one alarm is active, the relative marker is highlighted:
Press on the button “What to do” to show the online help: