background image

25

A Crane Co. Company

Limited 24 Month Warranty

Crane Pumps & Systems warrants that products of our manufacture will be free of defects in material and workmanship 
under  normal  use  and  service  for  twenty-four  (24)  months  after  manufacture  date,  when  installed  and  maintained 
in  accordance  with  our  instructions.This  warranty  gives  you  speci• c  legal  rights,  and  there  may  also  be  other  rights 
which vary from state to state. In the event the product is covered by the Federal Consumer Product Warranties Law 
(1)  the  duration  of  any  implied  warranties  associated  with  the  product  by  virtue  of  said  law  is  limited  to  the  same 
duration  as  stated  herein,  (2)  this  warranty  is  a  LIMITED  WARRANTY,  and  (3)  no  claims  of  any  nature  whatsoever 
shall  be  made  against  us,  until  the  ultimate  consumer,  his  successor,  or  assigns,  noti• es  us  in  writing  of  the  defect, 
and  delivers  the  product  and/or  defective  part(s)  freight  prepaid  to  our  factory  or  nearest  authorized  service  station. 
Some  states  do  not  allow  limitations  on  how  long  an  implied  warranty  lasts,  so  the  above  limitation  may  not  apply. 

THE SOLE AND EXCLUSIVE REMEDY FOR BREACH OF ANY AND ALL WARRANTIES WITH RESPECT TO ANY 
PRODUCT  SHALL  BE  TO  REPLACE  OR  REPAIR  AT  OUR  ELECTION,  F.O.B.  POINT  OF  MANUFACTURE  OR 
AUTHORIZED REPAIR STATION, SUCH PRODUCTS AND/OR PARTS AS PROVEN DEFECTIVE. THERE SHALL BE 
NO FURTHER LIABILITY, WHETHER BASED ON WARRANTY, NEGLIGENCE OR OTHERWISE.

 Unless expressly 

stated otherwise, guarantees in the nature of performance speci• cations furnished in addition to the foregoing material 
and  workmanship  warranties  on  a  product  manufactured  by  us,  if  any,  are  subject  to  laboratory  tests  corrected  for 
• eld performance. Any additional guarantees, in the nature of performance speci• cations must be in writing and such 
writing must be signed by our authorized representative. Due to inaccuracies in • eld testing if a con! ict arises between 
the  results  of  • eld  testing  conducted  by  or  for  user,  and  laboratory  tests  corrected  for  • eld  performance,  the  latter 
shall  control. 

RECOMMENDATIONS  FOR  SPECIAL  APPLICATIONS  OR  THOSE  RESULTING  FROM  SYSTEMS 

ANALYSES AND EVALUATIONS WE CONDUCT WILL BE BASED ON OUR BEST AVAILABLE EXPERIENCE AND 
PUBLISHED INDUSTRY INFORMATION. SUCH RECOMMENDATIONS DO NOT CONSTITUTE A WARRANTY OF 
SATISFACTORY PERFORMANCE AND NO SUCH WARRANTY IS GIVEN.

This  warranty  shall  not  apply  when  damage  is  caused  by  (a)  improper  installation,  (b)  improper  voltage  (c)  lightning 
(d) excessive sand or other abrasive material (e) scale or corrosion build-up due to excessive chemical content. Any 
modi• cation of the original equipment will also void the warranty. We will not be responsible for loss, damage or labor 
cost due to interruption of service caused by defective parts. Neither will we accept charges incurred by others without 
our prior written approval.
This warranty is void if our inspection reveals the product was used in a manner inconsistent with normal industry practice 
and\or  our  speci• c  recommendations.  The  purchaser  is  responsible  for  communication  of  all  necessary  information 
regarding the application and use of the product. 

UNDER NO CIRCUMSTANCES WILL WE BE RESPONSIBLE FOR 

ANY OTHER DIRECT OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO TRAVEL EXPENSES, 
RENTED  EQUIPMENT,  OUTSIDE  CONTRACTOR  FEES,  UNAUTHORIZED  REPAIR  SHOP  EXPENSES,  LOST 
PROFITS, LOST INCOME, LABOR CHARGES, DELAYS IN PRODUCTION, IDLE PRODUCTION, WHICH DAMAGES 
ARE  CAUSED  BY  ANY  DEFECTS  IN  MATERIAL  AND\OR  WORKMANSHIP  AND\OR  DAMAGE  OR  DELAYS  IN 
SHIPMENT.  THIS  WARRANTY  IS  EXPRESSLY  IN  LIEU  OF  ANY  OTHER  EXPRESS  OR  IMPLIED  WARRANTY, 
INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE

.

No rights extended under this warranty shall be assigned to any other person, whether by operation of law or otherwise, 
without our prior written approval.

420 Third Street 

83 West Drive

Piqua, Ohio 45356 

Brampton, Ont. Canada L6T 2J6

(937) 778-8947 

(905) 457-6223

Fax (937) 773-7157 

Fax (905) 457-2650

www.cranepumps.com

Summary of Contents for 4SE-HL Series

Page 1: ...reserves the right to change product without prior written noti cation 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773...

Page 2: ...8 20 CROSS SECTION 3450RPM Fig 12 21 EXPLODED VIEW 3450RPM Fig 13 22 PARTS LIST 23 24 RETURNED GOODS POLICY 25 WARRANT START UP REPORT WARRANTY REGISTRATION SPECIAL TOOLS AND EQUIPMENT INSULATION TEST...

Page 3: ...insert ngers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety d...

Page 4: ...ge Induction Winding Class F Class H Rated Magnet Wire Service Factor 1 15 SINGLE PHASE Capacitor Start Capacitor Run Requires BARNES Starter Panel Which includes capacitors and overload protection TH...

Page 5: ...Cage Induction Winding Class F Class H Rated Magnet Wire Service Factor 1 15 SINGLE PHASE Capacitor Start Capacitor Run Requires BARNES Starter Panel Which includes capacitors and overload protection...

Page 6: ...nits are self contained and are recommended for use in a sump lift station or basin This pump is designed to pump sewage ef uent or other nonexplosive or noncorrosive wastewater and shall NOT be insta...

Page 7: ...e situations may induce a false signal in the moisture detecting circuit If none of the above test prove conclusive the pump s should be pulled and the source of the failure identi ed and repaired IF...

Page 8: ...0 7 32 0 10 4 SOW 0 75 4SE11364L 11 3 200 3 1750 B 32 2 109 5 8 4 SOW 0 83 0 35 4SE11334L 11 3 230 3 1750 D 28 0 126 0 8 4 SOW 0 83 0 43 4SE11344L 11 3 460 3 1750 D 14 0 63 0 8 4 SOW 0 83 1 72 4SE1135...

Page 9: ...n oil into a clean dry container In separate container drain seal chamber by removing pipe plug 22 2 Check oil for contamination using an oil tester with a range to 30 Kilovolts breakdown 3 If oil is...

Page 10: ...ed in paragraph F 2 1 and disassemble seal plate and shaft seal as outlined in paragraph F 4 1 Drain oil from motor as outlined in paragraph F 1 3 Position unit upright using blocks to avoid resting u...

Page 11: ...46 remove impeller 28 as outlined in paragraph F 2 1 Drain oil from seal chamber as outlined in paragraph F 1 3 Remove cap screws 8 and lifting strap 7 Set unit upside down on blocks to avoid damaging...

Page 12: ...pusher until retainer engages spring 46C and spring is compressed slightly Make sure spring 46C is properly engaged in both retainers Slide seal plate 25 over shaft onto bearing bracket 21 being care...

Page 13: ...8 White 3 9 T4 T5 T6 Together THREE PHASE 480 600 VOLT AC Power Cable Motor Lead Number Green Ground Green Black 1 Red 2 White 3 T4 T7 Together T5 T8 Together T6 T9 Together MOISTURE AND TEMPERATURE S...

Page 14: ...e design con guration This number is used for ordering and obtaining information G 3 MODEL NUMBER This designation consists of numbers and letters which repre sent the discharge size series horsepower...

Page 15: ...impeller for freedom of operation security and condition Clean impeller and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set...

Page 16: ...16 FIGURE 10 4SEU Models ONLY 4SE 4SEU Pump Series...

Page 17: ...17 FIGURE 11 4SE 4SEU Pump Series...

Page 18: ...8 2 1 68 1 Cap Screw 1 2 13 x 1 1 4 lg Stainless 10 1 See Table 2 Conduit Box Cable Assembly 10a 1 Power Cable Not Sold Separately 10b 1 051447 Gland Nut 1 072559 Gland Nut For 7 5 11 3Hp 3Ph 15Hp 57...

Page 19: ...1150RPM 8 75 Dia 084894TS 084895TS 8 62 Dia 084894TT 084895TT 15HP 1750RPM 8 50 Dia 084894TU 084895TU 8 38 Dia 084894TV 084895TV 8 25 Dia 084894TW 084895TW 8 12 Dia 084894TX 084895TX 11 3HP 1750RPM 8...

Page 20: ...ring 53 5 016405 t Insulator 5 030149 t Insulator 7 5HP 1PH 15HP ONLY 54 1 052761 Wear Plate 4SEU s ONLY 55 4 1 130 1 Cap Screw 5 16 18 x 1 0 lg Stainless 56 4 20 2 1 Lockwasher 5 16 Stainless TABLE 2...

Page 21: ...21 4SE HL High Ef ciency Pump Series FIGURE 12...

Page 22: ...22 4SE HL High Ef ciency Pump Series FIGURE 13...

Page 23: ...on Ring 2 071431A Friction Ring For 7 5 11 3Hp 3Ph 15Hp 575V 2 110929 Friction Ring For 7 5HP 1PH 15HP ONLY 10d 1 051452 Grommet 1 071430A Grommet For 7 5 11 3Hp 3Ph 15Hp 575V 1 110928 Grommet For 7 5...

Page 24: ...ess 39 2 036803 Soc Hd Cap Screw 1 4 20 x 3 4 lg Stainless 41 1 036852 t Gasket 42 1 056668 t Square Ring 43 1 022879 Diaphragm Clamp Ring 44 4 002203 Cap Screw 1 4 20 x 7 8 lg Steel 46 1 039485 t Sha...

Page 25: ...s between the results of eld testing conducted by or for user and laboratory tests corrected for eld performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FR...

Page 26: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by t...

Page 27: ...O___ Type _________________________________ Number and size of short circuit device s ___________ Amp rating ___________________ Overload Type _____________ Size ______________ Amp rating ____________...

Page 28: ...rols installed away from turbulence YES___ NO___ Is level control operating properly YES___ NO___ Is pump fully submerged during operation YES___ NO___ Follow up Corrective Action Required YES___ NO__...

Reviews: