PARTS KITS

Seal Repair Kit...........P/N-130179
Overhaul Kit...............P/N-130175
Seal Tool Kit...............P/N-085737
Pressure Gauge Kit...P/N-085343

PARTS LIST - Standard

ITEM 

QTY 

PART NO. 

 

DESCRIPTION 

 

 

 

072688 

 

Motor-  

4SE4526L 

 

 

 

 

072689 

 

 

 

4SE4596L, 46L   

 

 

 

092867 

 

 

 

4SE4556L 

 

 

 

 

072690 

 

 

 

4SE7596L, 46L   

 

 

 

092868 

 

 

 

4SE7556L 

 

 

 

 

072691 

 

 

 

4SE11396L, 46L   

 

 

 

092869 

 

 

 

4SE11356L 

 

 

 

 

 072692 

 

 

 

4SE4524L 

 

 

 

 

072695 

 

 

 

4SE4564L 

 

 

 

 

072693 

 

 

 

4SE4534L, 44L   

 

 

 

092870 

 

 

 

4SE4554L 

 

 

 

 

072694 

 

 

 

4SE7524L 

 

 

 

 

072696 

 

 

 

4SE7564L 

 

 

 

 

072695 

 

 

 

4SE7534L, 44L   

 

 

 

092816 

 

 

 

4SE7554L 

 

 

 

 

072697 

 

 

 

4SE11364L 

 

 

 

 

072697 

 

 

 

4SE11334L, 44L   

 

 

 

092817 

 

 

 

4SE11354L 

 

 

 

 

072697 

 

 

 

4SE15034L, 44L   

 

 

 

092818 

 

 

 

4SE15054L 

 

 

 

 

072697 

 

 

 

4SEU15034L, 44L 

 

 

 

072697F 

 

 

 

4SEU15054L 

 

 

 

 

088795 

 

 

 

4SEU15032L, 42L 

 

 

 

088797 

 

 

 

4SEU15052L 

 

 

053030 

 

 

Motor Housing 

 

 

 

039734 

 

 

Ball Bearing 

 

 

 

070624 

 

 

Pipe Closure 

 

 

 

070623 

 

 

Pressure Relief Valve 

 

 

1-34-1 

 

 

Cap Screw,  

 

3/8-16 x 1” lg Stainless 

 

036863A 

 

 

S.S. Lifting Strap  

 

 

1-68-1 

 

 

Cap Screw,  

 

1/2-13 x 1-1/4” lg Stainless 

10 

See Table 2 

 

 

Conduit Box & Cable Assembly 

 

10a 

----- 

 

 

Power Cable  

 

 (Not Sold Separately)

10b 

051447 

 

Gland Nut 

 

 

 

 

072559 

 

Gland Nut,  

 

(For 7.5 & 11.3Hp 3Ph & 15Hp 575V) 

 

052259 

 

Gland Nut 

 

(For 7.5HP, 1PH & 15HP ONLY) 

10c 

051450 

 

Friction Ring 

 

 

 

 

071431A 

 

Friction Ring 

 

(For 7.5 & 11.3Hp 3Ph & 15Hp 575V) 

 

110929 

 

 

Friction Ring 

 

(For 7.5HP, 1PH & 15HP ONLY) 

10d 

051452 

 

Grommet 

 

 

 

071430A 

 

Grommet 

 

(For 7.5 & 11.3Hp 3Ph & 15Hp 575V) 

 

110928 

 

 

Grommet 

 

(For 7.5HP, 1PH & 15HP ONLY) 

10e 

----- 

 

Control Cable 

 

(Not Sold Separately)

10f 

051448 

 

Gland Nut 

 

 

 

10g 

021531 

 

Friction Ring 

 

 

 

10h 

066871 

 

Grommet 

 

 

 

10J 

030169 

 

Ground Screw 

10-32 x 5/8 Lg Stainless 

 

11 

051937 

 

ªt

  Square Ring 

 

 

12 

016406 

 

t

 

Connector  

 

 

 

 

030148 

 

t

 

Connector 

(7.5HP,1PH & 15HP ONLY) 

13 

2.5 Gal  029034 

 

 

Oil - Motor Housing 

 

 

 

35 oz.   

 

 

Oil - Seal Cavity

14 

 

 

 

Machine Screw  6-32 x 1/4 Cad. Plt. Steel  5-32-6

15 

052563 

 

 

 

Lockwasher 

 

No. 6 Steel 

 

4SE & 4SEU Pump Series

(*) Included with item number 10.

(

ª

) 11, 32, 33, 34, 35, 41, 42, 46

(

t

)  11, 12, 16, 17, 32, 33, 35, 36, 37, 41, 42, 46, 47, 53

Summary of Contents for 4SE-HL Series

Page 1: ...reserves the right to change product without prior written noti cation 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773...

Page 2: ...8 20 CROSS SECTION 3450RPM Fig 12 21 EXPLODED VIEW 3450RPM Fig 13 22 PARTS LIST 23 24 RETURNED GOODS POLICY 25 WARRANT START UP REPORT WARRANTY REGISTRATION SPECIAL TOOLS AND EQUIPMENT INSULATION TEST...

Page 3: ...insert ngers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety d...

Page 4: ...ge Induction Winding Class F Class H Rated Magnet Wire Service Factor 1 15 SINGLE PHASE Capacitor Start Capacitor Run Requires BARNES Starter Panel Which includes capacitors and overload protection TH...

Page 5: ...Cage Induction Winding Class F Class H Rated Magnet Wire Service Factor 1 15 SINGLE PHASE Capacitor Start Capacitor Run Requires BARNES Starter Panel Which includes capacitors and overload protection...

Page 6: ...nits are self contained and are recommended for use in a sump lift station or basin This pump is designed to pump sewage ef uent or other nonexplosive or noncorrosive wastewater and shall NOT be insta...

Page 7: ...e situations may induce a false signal in the moisture detecting circuit If none of the above test prove conclusive the pump s should be pulled and the source of the failure identi ed and repaired IF...

Page 8: ...0 7 32 0 10 4 SOW 0 75 4SE11364L 11 3 200 3 1750 B 32 2 109 5 8 4 SOW 0 83 0 35 4SE11334L 11 3 230 3 1750 D 28 0 126 0 8 4 SOW 0 83 0 43 4SE11344L 11 3 460 3 1750 D 14 0 63 0 8 4 SOW 0 83 1 72 4SE1135...

Page 9: ...n oil into a clean dry container In separate container drain seal chamber by removing pipe plug 22 2 Check oil for contamination using an oil tester with a range to 30 Kilovolts breakdown 3 If oil is...

Page 10: ...ed in paragraph F 2 1 and disassemble seal plate and shaft seal as outlined in paragraph F 4 1 Drain oil from motor as outlined in paragraph F 1 3 Position unit upright using blocks to avoid resting u...

Page 11: ...46 remove impeller 28 as outlined in paragraph F 2 1 Drain oil from seal chamber as outlined in paragraph F 1 3 Remove cap screws 8 and lifting strap 7 Set unit upside down on blocks to avoid damaging...

Page 12: ...pusher until retainer engages spring 46C and spring is compressed slightly Make sure spring 46C is properly engaged in both retainers Slide seal plate 25 over shaft onto bearing bracket 21 being care...

Page 13: ...8 White 3 9 T4 T5 T6 Together THREE PHASE 480 600 VOLT AC Power Cable Motor Lead Number Green Ground Green Black 1 Red 2 White 3 T4 T7 Together T5 T8 Together T6 T9 Together MOISTURE AND TEMPERATURE S...

Page 14: ...e design con guration This number is used for ordering and obtaining information G 3 MODEL NUMBER This designation consists of numbers and letters which repre sent the discharge size series horsepower...

Page 15: ...impeller for freedom of operation security and condition Clean impeller and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set...

Page 16: ...16 FIGURE 10 4SEU Models ONLY 4SE 4SEU Pump Series...

Page 17: ...17 FIGURE 11 4SE 4SEU Pump Series...

Page 18: ...8 2 1 68 1 Cap Screw 1 2 13 x 1 1 4 lg Stainless 10 1 See Table 2 Conduit Box Cable Assembly 10a 1 Power Cable Not Sold Separately 10b 1 051447 Gland Nut 1 072559 Gland Nut For 7 5 11 3Hp 3Ph 15Hp 57...

Page 19: ...1150RPM 8 75 Dia 084894TS 084895TS 8 62 Dia 084894TT 084895TT 15HP 1750RPM 8 50 Dia 084894TU 084895TU 8 38 Dia 084894TV 084895TV 8 25 Dia 084894TW 084895TW 8 12 Dia 084894TX 084895TX 11 3HP 1750RPM 8...

Page 20: ...ring 53 5 016405 t Insulator 5 030149 t Insulator 7 5HP 1PH 15HP ONLY 54 1 052761 Wear Plate 4SEU s ONLY 55 4 1 130 1 Cap Screw 5 16 18 x 1 0 lg Stainless 56 4 20 2 1 Lockwasher 5 16 Stainless TABLE 2...

Page 21: ...21 4SE HL High Ef ciency Pump Series FIGURE 12...

Page 22: ...22 4SE HL High Ef ciency Pump Series FIGURE 13...

Page 23: ...on Ring 2 071431A Friction Ring For 7 5 11 3Hp 3Ph 15Hp 575V 2 110929 Friction Ring For 7 5HP 1PH 15HP ONLY 10d 1 051452 Grommet 1 071430A Grommet For 7 5 11 3Hp 3Ph 15Hp 575V 1 110928 Grommet For 7 5...

Page 24: ...ess 39 2 036803 Soc Hd Cap Screw 1 4 20 x 3 4 lg Stainless 41 1 036852 t Gasket 42 1 056668 t Square Ring 43 1 022879 Diaphragm Clamp Ring 44 4 002203 Cap Screw 1 4 20 x 7 8 lg Steel 46 1 039485 t Sha...

Page 25: ...s between the results of eld testing conducted by or for user and laboratory tests corrected for eld performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FR...

Page 26: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by t...

Page 27: ...O___ Type _________________________________ Number and size of short circuit device s ___________ Amp rating ___________________ Overload Type _____________ Size ______________ Amp rating ____________...

Page 28: ...rols installed away from turbulence YES___ NO___ Is level control operating properly YES___ NO___ Is pump fully submerged during operation YES___ NO___ Follow up Corrective Action Required YES___ NO__...