background image

29

1

103587A

Seal Housing

All double seal

31

1

105145

Spacer Ring

32

1

2-27008-62

Retaining Ring

All double seal

33

1

Impeller, Brass

107032TE

4.62 Dia. (STD for a 2.0 HP)

107032TF

4.50 Dia.

107032TG

4.37 Dia. (STD for a 1.5 HP)

107032TH

4.25 Dia.

107032TJ

4.12 Dia.

107032TK

4.00 Dia.

107032TL

3.88 Dia.

36

2

027344

Gasket

39

1

014270

Pipe Plug

.375" NPT, ZP

40

2

1-36-1

Hex. Hd. Cap Screw

2" Discharge, 3/8-16 x 1.25" Lg., Stainless

1-131-1

Hex. Hd. Cap Screw

3" Discharge, 5/16-18 x 1.25" Lg., Stainless

41

A/R

Loctite 242

42

A/R

Permatex 2C

43

2

082727

Washer

2" Discharge, 3/8" Stainless

44

1

003217

Pipe Plug

All double seal, .25" NPT, ZP

45

2

5-32-6

Screw

(Optional) for moisture sensor, #6-32 x .25" Lg., ZP

46

2

052563

Lockwasher

(Optional) for moisture sensor #6 Stl.

47

2

084948

Socket Head Screw

1/4-20 x 1.25" Lg., Stainless

48

1

105150

Terminal Connector

200-240V, 3Ph

3

625-00163

Terminal Connector

480V, 3PH

48A

3

085078

Blue-Butt Connector

480V, 3PH

49

3

105149

Wire Assembly

200-240V, 3Ph

50

1

051621

Thermal Sensor

(Optional) for temperature sensor, (Not Shown)

51

2

105155

Wire Assembly

(Optional) for temperature sensor, (Not Shown)

52

2

625-00163

Terminal Connector

(Optional) for temperature sensor, (Not Shown)

53

2

105106

Wire Assembly

(Optional) for moisture sensor

54

1

103584

Terminal Block

Temperature sensor options

103585

Moisture and temp. sensor options

56

1

See Table 2

Control Cable

(Optional) for moisture and/or temp. sensors

56a

1

103582

Compression Flange

Included with Cable Set

57

A/R

Loctite 609

64

2

030337

Socket Head Cap Screw

Double seal Only, 1/4-20 x 2" Lg., Stainless

65

1

625-02117

Sleeve, Fiberglass

TABLE 2 - POWER & SENSOR CABLE SETS

CABLE

LENGTH

ITEM #16

240 VOLT

1 PHASE

ITEM #16

3 PHASE

ITEM #56

(OPTIONAL)

Temperature - 3 Phase 

ITEM #56

(OPTIONAL)

Moisture and Temperature 

Sensor 3 Phase

or Moisture Sensor 

8 FT

----

103742A

103741A

103740A

15 FT

109498

103742

103741

103740

20 FT 

 (Std)

109498XA

103742XA

103741XA

103740XA

30 FT

109498XC

103742XC

103741XC

103740XC

50 FT

109498XF

103742XF

103741XF

103740XF

75 FT

109498XJ

103742XJ

103741XJ

103740XJ

100 FT

109498XL

103742XL

103741XL

103740XL

23

Summary of Contents for 2SEV

Page 1: ...such Crane Pumps Systems Inc reserves the right to change product without prior written notification SERIES 2SEV 3SEV L DS 1 5 2 0 HP 3450 RPM Single and Double Seal BARNES 420 Third Street P O Box 6...

Page 2: ...BLE SEAL CROSS SECTION Fig 17 20 DOUBLE SEAL EXPLODED VIEW Fig 18 21 PARTS LIST 22 23 RETURNED GOODS POLICY 25 WARRANTY START UP REPORT WARRANTY REGISTRATION SPECIAL TOOLS AND EQUIPMENT INSULATION TES...

Page 3: ...n and discharge openings DO NOT insert fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO...

Page 4: ...0 Volt Custom Molded for Sealing and Strain Relief SPEED 3450 RPM Nominal UPPER BEARING Design Single Row Ball Lubrication Oil Load Radial LOWER BEARING Design Single Row Ball Lubrication Oil Load Rad...

Page 5: ...12 63 321 6 25 159 1 50 38 4 88 124 9 75 248 20 78 528 6 66 169 3SEV L Series 13 99 355 7 06 179 2 06 52 4 88 124 9 75 248 19 07 484 9 03 229 3SEV DS Series 13 99 355 7 06 179 2 06 52 4 88 124 9 75 2...

Page 6: ...d provided 1 The pump is not installed under water for more than one 1 month 2 Immediately upon satisfactory completion of the test the pump is removed thoroughly dried repacked in the original shippi...

Page 7: ...dings become too hot and will automatically reset itself when the pump motor cools to a safe temperature It is recommended that the thermal sensor be connected in series to an alarm device to alert th...

Page 8: ...70 3SEV1522L 1 5 240 1 3450 A 13 5 31 5 12 3 SOW 0 610 2 15 12 49 3SEV1592L 1 5 200 240 3 3450 C 11 5 10 5 27 0 14 4 SOW 0 600 4 22 3SEV1542L 1 5 480 3 3450 F 5 2 13 5 14 4 SOW 0 600 17 0 3SEV1552L 1...

Page 9: ...and refill with new oil as per section F 1 4 SECTION D START UP OPERATION D 1 Check Voltage and Phase Before operating pump compare the voltage and phase information stamped on the pump identificatio...

Page 10: ...emely fast increase pressure by tapping air nozzle Too much pressure will damage seal DO NOT exceed 10 P S I F 1 4 Replacing Oil Motor Housing Set unit upright and refill with new cooling oil as per T...

Page 11: ...ew into volute 1 Torque to 100 in lbs Check for free rotation of motor and impeller F 3 Shaft Seal Service Important Handle seal parts with extreme care DO NOT scratch or mar lapped surfaces F 3 1 Dis...

Page 12: ...d or resting on bellows tail Slide retaining ring 28d over shaft and let rest on spring 28c Replace snap ring 32 in groove of shaft Set square ring 27 in groove on outer seal plate 29 and place outer...

Page 13: ...or winding for shorts and check resistance values Check rotor for wear If rotor or the stator windings are defective the complete motor must be replaced Important All parts must be clean before reasse...

Page 14: ...ads to the underside of the terminal block s 21 54 optional as shown in Figure 13 Note that the pins are numbered underneath the terminal block Place o ring 20 into groove in terminal block and lubric...

Page 15: ...Fig 13 15...

Page 16: ...uration This number is used for ordering and obtaining information G 3 MODEL NUMBER This designation consists of numbers and letters which represent the discharge size series horsepower motor phase an...

Page 17: ...lean impeller cavity and inlet of any obstruction 9 Loosen union slightly to allow trappedair to escape Verify that turn off level of switch is set so that impeller cavity is always flooded Clean vent...

Page 18: ...Fig 15 2SEV L 3SEV L Series Single Seal 18...

Page 19: ...Fig 16 2SEV L 3SEV L Series Single Seal 19...

Page 20: ...Fig 17 2SEV DS 3SEV DS Series Double Seal 20...

Page 21: ...Fig 18 2SEV DS 3SEV DS Series Double Seal 21...

Page 22: ...x 75 Lg Stainless 6 1 129 1 Hex Hd Cap Screw Optional for moisture and temp sensors 12 8 026322 Lockwasher Std 5 16 Stainless 10 026322 Lockwasher Optional for moisture and temp sensors 13 1 103503 Ha...

Page 23: ...Wire Assembly 200 240V 3Ph 50 1 051621 Thermal Sensor Optional for temperature sensor Not Shown 51 2 105155 Wire Assembly Optional for temperature sensor Not Shown 52 2 625 00163 Terminal Connector Op...

Page 24: ...NOTES 24...

Page 25: ...f the warranty contact your local Crane Pumps Systems Inc Distributor RETURNED GOODS RETURN OF MERCHANDISE REQUIRES A RETURNED GOODS AUTHORIZATION CONTACT YOUR LOCAL CRANE PUMPS SYSTEMS INC DISTRIBUTO...

Page 26: ...eld performance Any additional guarantees in the nature of performance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field t...

Page 27: ...ottom Does Impeller Turn Freely By Hand YES NO Condition Of Equipment GOOD FAIR POOR Condition Of Cable Jacket GOOD FAIR POOR Resistance of Cable Jacket GOOD FAIR POOR Resistance of Cable and Pump Mot...

Page 28: ...Pump Off L1 L2 L2 L3 L3 L1 Voltage supply at panel line connection Pump On L1 L2 L2 L3 L3 L1 Amperage Load connection Pump On L1 L2 L3 FINAL CHECK Is pump seated on discharge properly Check for leaks...

Page 29: ...ottom Does Impeller Turn Freely By Hand YES NO Condition Of Equipment GOOD FAIR POOR Condition Of Cable Jacket GOOD FAIR POOR Resistance of Cable Jacket GOOD FAIR POOR Resistance of Cable and Pump Mot...

Page 30: ...Pump Off L1 L2 L2 L3 L3 L1 Voltage supply at panel line connection Pump On L1 L2 L2 L3 L3 L1 Amperage Load connection Pump On L1 L2 L3 FINAL CHECK Is pump seated on discharge properly Check for leaks...

Page 31: ...RIAL NO PART NO BRAND FOLD HERE IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty Complete the Warranty Registration Form and returned to Crane Pumps Systems Inc Warrant...

Page 32: ...CRANE PUMPS SYSTEMS INC WARRANTY SERVICE GROUP 420 THIRD STREET P O BOX 603 PIQUA OHIO 45356 0603 U S A PLACE STAMP HERE FOLD HERE AND TAPE DO NOT STAPLE...

Reviews: