background image

PARTS KITS

Seal Repair Kits:

Single Seal:......P/N - 
Double Seal:.....P/N - 

Seal Tool Kit:.................P/N - 107271
Pressure Gauge Kit......P/N - 085343

PARTS LIST

ITEM

QTY.

PART NO.

DESCRIPTION

1

1

055400

Volute

2

1

069140

Gasket

3

1

026210

Flange, 2" Discharge

105153

Flange, 3" Discharge

4

2

003217

Pipe Plug

All double seal (Std), .25" NPT, ZP

2

039383

Moisture Sensor Probes

(Optional) for moisture sensor

5

1

084343

Seal Plate

All single seal

084429

All double seal

6

1

105196

Motor Housing

(Std)

105196HA

(Optional) for moisture and temp. sensors

7

1

Motor:

780161

2SEV1522DS, 2SEV2022DS, 3SEV1522DS, 3SEV2022DS

780162

2SEV1592DS, 2SEV2092DS, 3SEV1592DS, 3SEV2092DS

780162

2SEV1544DS, 2SEV2044DS, 3SEV1544DS, 3SEV2044DS

780163

2SEV1552DS, 2SEV2052DS, 3SEV1552DS, 3SEV2052DS

780131

2SEV1522L, 2SEV2022L, 3SEV1522L, 3SEV2022L

780133

2SEV1592L, 2SEV2092L, 3SEV1592L, 3SEV2092L

780133

2SEV1542L, 2SEV2042L, 3SEV1542L, 3SEV2042L

780132

2SEV1552L, 2SEV2052L, 3SEV1552L, 3SEV2052L

8

96oz

029034

Oil

All single seal

120oz

029034

Oil

All double seal (Includes 24oz. in Seal Chamber)

9

1

036391

Capacitor

1 Phase,

10

1

039858

Capacitor Bracket

1 Phase

11

4

1-129-1

Hex. Hd. Cap Screw

(Std), 5/16-18 x .75" Lg., Stainless

6

1-129-1

Hex. Hd. Cap Screw

(Optional) for moisture and temp. sensors

12

8

026322

Lockwasher

(Std), 5/16, Stainless

10

026322

Lockwasher

(Optional) for moisture and temp. sensors

13

1

103503

Handle

16

1

See Table 2

Power Cable Set

19

1

105197

Snap Ring

(Std)

2

105197

Snap Ring

(Optional) for moisture and temp. sensors

20

1

2-31051-224

O-ring

(Std)

2

2-31051-224

O-ring

(Optional) for moisture and temp. sensors

21

1

103760

Terminal Block

1 Phase

103583

3 Phase

22

1

105111

Ground Wire Assembly

3 Phase

1

105111A

Ground Wire Assembly

1 Phase

2

105111

Ground Wire Assembly

(Optional) for moisture and temp. sensors

23

1

016660

Screw, Self Tapping

#8-32 x .375" Lg., Stainless

24

1

061143

Retaining Ring

25

1

039734

Bearing

26

4

1-158-1

Cap Screw

All single seal, 5/16-18 x 2.50" Lg., Stainless

0116491

All double seal

27

1

027269

Square Ring

All single seal

2

027269

Square Ring

All double seal

28

1

Shaft Seal:

 (Qty 2 for DS)

067562

Carbon/Ceramic/Buna-N (STD)

067562SB

Tungsten/Tungsten/Buna-N

067562SD

Silicon Carbide/Silicon Carbide/Buna-N

067562SF

Carbon/Ceramic/Viton

067562SH

Tungsten/Tungsten/Viton

067562SK

Silicon Carbide/Silicon Carbide/Viton

067562SM

Silicon Carbide/Tungsten/Buna-N

067562SN

Carbon/Ni-Resistant/Buna-N

067562SP

Carbon/Ni-Resistant/Neoprene

(†) 2, 12, 26, 28, 36, 39, 40, 43.

(

) 2, 12, 26, 27, 28, 32, 36, 39, 40, 43, 44.

22

Summary of Contents for 2SEV

Page 1: ...such Crane Pumps Systems Inc reserves the right to change product without prior written notification SERIES 2SEV 3SEV L DS 1 5 2 0 HP 3450 RPM Single and Double Seal BARNES 420 Third Street P O Box 6...

Page 2: ...BLE SEAL CROSS SECTION Fig 17 20 DOUBLE SEAL EXPLODED VIEW Fig 18 21 PARTS LIST 22 23 RETURNED GOODS POLICY 25 WARRANTY START UP REPORT WARRANTY REGISTRATION SPECIAL TOOLS AND EQUIPMENT INSULATION TES...

Page 3: ...n and discharge openings DO NOT insert fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO...

Page 4: ...0 Volt Custom Molded for Sealing and Strain Relief SPEED 3450 RPM Nominal UPPER BEARING Design Single Row Ball Lubrication Oil Load Radial LOWER BEARING Design Single Row Ball Lubrication Oil Load Rad...

Page 5: ...12 63 321 6 25 159 1 50 38 4 88 124 9 75 248 20 78 528 6 66 169 3SEV L Series 13 99 355 7 06 179 2 06 52 4 88 124 9 75 248 19 07 484 9 03 229 3SEV DS Series 13 99 355 7 06 179 2 06 52 4 88 124 9 75 2...

Page 6: ...d provided 1 The pump is not installed under water for more than one 1 month 2 Immediately upon satisfactory completion of the test the pump is removed thoroughly dried repacked in the original shippi...

Page 7: ...dings become too hot and will automatically reset itself when the pump motor cools to a safe temperature It is recommended that the thermal sensor be connected in series to an alarm device to alert th...

Page 8: ...70 3SEV1522L 1 5 240 1 3450 A 13 5 31 5 12 3 SOW 0 610 2 15 12 49 3SEV1592L 1 5 200 240 3 3450 C 11 5 10 5 27 0 14 4 SOW 0 600 4 22 3SEV1542L 1 5 480 3 3450 F 5 2 13 5 14 4 SOW 0 600 17 0 3SEV1552L 1...

Page 9: ...and refill with new oil as per section F 1 4 SECTION D START UP OPERATION D 1 Check Voltage and Phase Before operating pump compare the voltage and phase information stamped on the pump identificatio...

Page 10: ...emely fast increase pressure by tapping air nozzle Too much pressure will damage seal DO NOT exceed 10 P S I F 1 4 Replacing Oil Motor Housing Set unit upright and refill with new cooling oil as per T...

Page 11: ...ew into volute 1 Torque to 100 in lbs Check for free rotation of motor and impeller F 3 Shaft Seal Service Important Handle seal parts with extreme care DO NOT scratch or mar lapped surfaces F 3 1 Dis...

Page 12: ...d or resting on bellows tail Slide retaining ring 28d over shaft and let rest on spring 28c Replace snap ring 32 in groove of shaft Set square ring 27 in groove on outer seal plate 29 and place outer...

Page 13: ...or winding for shorts and check resistance values Check rotor for wear If rotor or the stator windings are defective the complete motor must be replaced Important All parts must be clean before reasse...

Page 14: ...ads to the underside of the terminal block s 21 54 optional as shown in Figure 13 Note that the pins are numbered underneath the terminal block Place o ring 20 into groove in terminal block and lubric...

Page 15: ...Fig 13 15...

Page 16: ...uration This number is used for ordering and obtaining information G 3 MODEL NUMBER This designation consists of numbers and letters which represent the discharge size series horsepower motor phase an...

Page 17: ...lean impeller cavity and inlet of any obstruction 9 Loosen union slightly to allow trappedair to escape Verify that turn off level of switch is set so that impeller cavity is always flooded Clean vent...

Page 18: ...Fig 15 2SEV L 3SEV L Series Single Seal 18...

Page 19: ...Fig 16 2SEV L 3SEV L Series Single Seal 19...

Page 20: ...Fig 17 2SEV DS 3SEV DS Series Double Seal 20...

Page 21: ...Fig 18 2SEV DS 3SEV DS Series Double Seal 21...

Page 22: ...x 75 Lg Stainless 6 1 129 1 Hex Hd Cap Screw Optional for moisture and temp sensors 12 8 026322 Lockwasher Std 5 16 Stainless 10 026322 Lockwasher Optional for moisture and temp sensors 13 1 103503 Ha...

Page 23: ...Wire Assembly 200 240V 3Ph 50 1 051621 Thermal Sensor Optional for temperature sensor Not Shown 51 2 105155 Wire Assembly Optional for temperature sensor Not Shown 52 2 625 00163 Terminal Connector Op...

Page 24: ...NOTES 24...

Page 25: ...f the warranty contact your local Crane Pumps Systems Inc Distributor RETURNED GOODS RETURN OF MERCHANDISE REQUIRES A RETURNED GOODS AUTHORIZATION CONTACT YOUR LOCAL CRANE PUMPS SYSTEMS INC DISTRIBUTO...

Page 26: ...eld performance Any additional guarantees in the nature of performance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field t...

Page 27: ...ottom Does Impeller Turn Freely By Hand YES NO Condition Of Equipment GOOD FAIR POOR Condition Of Cable Jacket GOOD FAIR POOR Resistance of Cable Jacket GOOD FAIR POOR Resistance of Cable and Pump Mot...

Page 28: ...Pump Off L1 L2 L2 L3 L3 L1 Voltage supply at panel line connection Pump On L1 L2 L2 L3 L3 L1 Amperage Load connection Pump On L1 L2 L3 FINAL CHECK Is pump seated on discharge properly Check for leaks...

Page 29: ...ottom Does Impeller Turn Freely By Hand YES NO Condition Of Equipment GOOD FAIR POOR Condition Of Cable Jacket GOOD FAIR POOR Resistance of Cable Jacket GOOD FAIR POOR Resistance of Cable and Pump Mot...

Page 30: ...Pump Off L1 L2 L2 L3 L3 L1 Voltage supply at panel line connection Pump On L1 L2 L2 L3 L3 L1 Amperage Load connection Pump On L1 L2 L3 FINAL CHECK Is pump seated on discharge properly Check for leaks...

Page 31: ...RIAL NO PART NO BRAND FOLD HERE IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty Complete the Warranty Registration Form and returned to Crane Pumps Systems Inc Warrant...

Page 32: ...CRANE PUMPS SYSTEMS INC WARRANTY SERVICE GROUP 420 THIRD STREET P O BOX 603 PIQUA OHIO 45356 0603 U S A PLACE STAMP HERE FOLD HERE AND TAPE DO NOT STAPLE...

Reviews: