background image

Manual 2100-635A
Page 

4 of 18

LEGEND:

VLT  =  Ventilation Load – Total
VLS  =  Ventilation Load – Sensible
VLL  =  Ventilation Load – Latent
HRT  =  Heat Recovery – Total
HRS  =  Heat Recovery – Sensible
HRL  =  Heat Recovery – Latent
WVL  =  Winter Ventilation Load
WHR  =  Winter Heat Recovery

Winter Heating Performance

(Indoor Design Conditions 70°F DB)

NOTE:  

All performance data is based on 

operating intake and exhaust blower on 

the same speed.

Ambient

OD

Ventilation Rate 450 CFM

Ventilation Rate 375 CFM

Ventilation Rate 300 CFM

DB/

WB

F

VLT

VLS

VLL

HRT

HRS

HRL

VLT

VLS

VLL

HRT

HRS

HRL

VLT

VLS

VLL

HRT

HRS

HRL

105

75
70
65

21465
14580
14580

14580
14580
14580

6884

0
0

13952

9477
9477

9477
9477
9477

4475

0
0

17887
12150
12150

12150
12150
12150

5737

0
0

11805

8018
8018

8018
8018
8018

3786

0
0

14310

9720
9720

9720
9720
9720

4590

0
0

9587
6512
6512

6512
6512
6512

3075

0
0

100

80
75
70
65
60

31590
21465
12352
12150
12150

12150
12150
12150
12150
12150

19440

9314

202

0
0

20533
13952

8029
7897
7897

7897
7897
7897
7897
7897

12635

6054

131

0
0

26325
17887
10293
10125
10125

10125
10125
10125
10125
10125

16200

7762

168

0
0

17374
11805

6793
6682
6682

6682
6682
6682
6682
6682

10692

5123

111

0
0

21060
14310

8235
8100
8100

8100
8100
8100
8100
8100

12960

6210

135

0
0

14110

9587
5517
5427
5427

5427
5427
5427
5427
5427

8683
4160

90

0
0

95

80
75
70
65
60

31590
21465
12352

9720
9720

9720
9720
9720
9720
9720

21870
11744

2632

0
0

20553
13952

8029
6318
6318

6318
6318
6318
6318
6318

14215

7634
1711

0
0

26325
17887
10293

8100
8100

8100
8100
8100
8100
8100

18225

9787
2193

0
0

17374
11805

6793
5345
5345

5345
5345
5345
5345
5345

12028

6459
1447

0
0

21060
14310

8235
6480
6480

6480
6480
6480
6480
6480

14580

7830
1755

0
0

14110

9587
5517
4341
4341

4341
4341
4341
4341
4341

9768
5246
1175

0
0

90

80
75
70
65
60

31590
21465
12352

7290
7290

7290
7290
7290
7290
7290

24300
14175

5062

0
0

20533
13952

8029
4738
4738

4738
4738
4738
4738
4738

15794

9213
3290

0
0

26325
17887
10293

6075
6075

6075
6075
6075
6075
6075

20250
11812

4218

0
0

17374
11805

6793
4009
4009

4009
4009
4009
4009
4009

13365

7796
2784

0
0

21060
14310

8235
4860
4860

4860
4860
4860
4860
4860

16200

9450
3375

0
0

14110

9587
5517
3256
3256

3256
3256
3256
3256
3256

10854

6331
2261

0
0

85

80
75
70
65
60

31590
21465
12352

4860
4860

4860
4860
4860
4860
4860

26730
16605

7492

0
0

20533
13952

8029
3159
3159

3159
3159
3159
3159
3159

17374
10793

4870

0
0

26325
17887
10293

4050
4050

4050
4050
4050
4050
4050

22275
13837

6243

0
0

17374
11805

6793
2672
2672

2672
2672
2672
2672
2672

14701

9132
4120

0
0

21060
14310

8235
3240
3240

3240
3240
3240
3240
3240

17820
11070

4995

0
0

14110

9587
5517
2170
2170

2170
2170
2170
2170
2170

11939

7416
3346

0
0

80

75
70
65
60

21465
12352

4252
2430

2430
2430
2430
2430

19035

9922
1822

0

13952

8029
2764
1579

1579
1579
1579
1579

12372

6449
1184

0

17887
10293

3543
2025

2025
2025
2025
2025

15862

8268
1518

0

11805

6793
2338
1336

1336
1336
1336
1336

10469

5457
1002

0

14310

8235
2835
1620

1620
1620
1620
1620

12690

6615
1215

0

9587
5517
1899
1085

1085
1085
1085
1085

8502
4432

814

0

75

70
65
60

12352

4252

0

0
0
0

12352

4252

0

8029
2764

0

0
0
0

8029
2764

0

10293

3543

0

0
0
0

10293

3543

0

6793
2338

0

0
0
0

6793
2338

0

8235
2835

0

0
0
0

8235
2835

0

5517
1899

0

0
0
0

5517
1899

0

Ambient

OD

Ventilation Rate

450 CFM

375 CFM

300 CFM

DB/°F

WVL

WHR

WVL

WHR

WVL

WHR

65

2430

1944

2025

1640

1620

1328

60

4860

3888

4050

3280

3240

2656

55

7290

5832

6075

4920

4860

3985

50

9720

7776

8100

6561

6480

5313

45

12150

9720

10125

8201

8100

6642

40

14580

11664

12150

9841

9720

7970

35

17010

13608

14175

11481

11340

9298

30

19440

15552

16200

13122

12960

10627

25

21870

17496

18225

14762

14580

11955

20

24300

19440

20250

16402

16200

13284

15

26730

21384

22275

18042

17820

14612

NOTE:

  Sensible performance only is shown for winter 

application.

PERFORMANCE AND APPLICATION DATA – WERVP*5

Summer Cooling Performance

(Indoor Design Conditions 75°DB/62°WB)

Summary of Contents for WERVPA5

Page 1: ...ND OUTDOOR AIR SHUT OFF DAMPER Models INSTALLATION INSTRUCTIONS WERVPA5 WERVPC5 Bard Manufacturing Company Inc Bryan Ohio 43506 www bardhvac com Manual 2100 635A Supersedes 2100 635 Date 3 21 18 For U...

Page 2: ...Assembly and Discard Shipping Plate 5 Figure 2 Remove Access Panels 6 Figure 3 Remove Air Filter and Exhaust Cover Plate 7 Figure 4 Install Exhaust Blower Assembly 8 Figure 5 Plug Exhaust Blower Into...

Page 3: ...mmer and winter conditions Provides required ventilation to meet the requirements of ASHRAE 62 1 standard NOTE During operation below 5 F outdoor temperature freezing of moisture in the heat transfer...

Page 4: ...0 20533 13952 8029 4738 4738 4738 4738 4738 4738 4738 15794 9213 3290 0 0 26325 17887 10293 6075 6075 6075 6075 6075 6075 6075 20250 11812 4218 0 0 17374 11805 6793 4009 4009 4009 4009 4009 4009 4009...

Page 5: ...1 or 3 phase WERVPC5 W42AA W42HA C W48AA W48HA C W60AA W60HA C W72AB C 460 3 phase FIGURE 1 Remove Blower Assembly and Discard Shipping Plate MIS 2233 Discard Shipping plate Remove Exhaust Blower Ass...

Page 6: ...r filter access and service access panels on the Bard wall mount unit see Figure 2 Save the filter access panel and discard service access panel FIGURE 2 Remove Access Panels MIS 3744 SERVICE ACCESS D...

Page 7: ...emove and discard the exhaust cover plate and remove center screw from condenser grille FIGURE 3 Remove Air Filter and Exhaust Cover Plate MIS 3745 REMOVE DISCARD EXHUAST PLATE COVER UNIT AIR FILTER R...

Page 8: ...n top of condenser partition see Figure 5 inset This is important to insure proper drainage of any water entering damper assembly 8 Remove access panel and plug in exhaust blower as shown in Figure 5...

Page 9: ...k together see Figure 5 MIS 3747 VENTILATOR SIDE SECTION VIEW GRILL AND SERVICE DOOR BETWEEN THE CONDENSER PARTITION SERVICE DOOR CONDENSER LIP OF ERV IS TO BE HEAT RECOVERY FRONT GRILLE GRILLE TO INS...

Page 10: ...3748 LOW VOLTAGE AS SHOWN AND WIRE INSTALL 1 480701 0 CAP RECOVERY ASSEMBLY INPUT FROM HEAT PER WIRE DIAGRAM HIGH VOLTAGE WIRES GROUND WIRE NOTE These 24 volt control wires control the starting and st...

Page 11: ...tor checkout 14 Re install the blower access and filter access panels at top of unit and secure with sheet metal screws 15 Replace the vent option access panel with the new panel provided Attach air i...

Page 12: ...3 Run the WERVP only during periods when the conditioned space is occupied Running the WERVP during unoccupied periods wastes energy decreases the expected life of the WERVP and can result in a large...

Page 13: ...ARNING Open disconnect to shut all power OFF before changing motor speeds Failure to do so could result in injury or death due to electrical shock FIGURE 9 Airflow Diagram MIS 3750 ROOM AIR CONDENSER...

Page 14: ...1 Humidity W1 E D YO Brown White Y1 L W2 R A Y2 G L 1 W3 8 Heat Pump Y1 C G R Y2 B W1 W2 A 2 D Wall Mount ONLY NEEDED IF DEHUMIDIFICATION IS USED 1 PROGRAM THERMOSTAT FOR CONTINUOUS BLOWER DURING OCC...

Page 15: ...VAC INPUT CO2 OUTPUT TEMP OUTPUT W2 2 3 6 Brown White Red White RT 1 W1 E Orange Black White C Thermostat With D A W2 B W1 L ONLY NEEDED IF DEHUMIDIFICATION IS USED Optional CO Controller Humidity Hea...

Page 16: ...ation systems energy transfer surfaces must be accessible for washing to remove oils grease tars and dirt that can impede performance or generate odors Washing of the desiccant surfaces is required to...

Page 17: ...moval capacity it is recommended that the energy recovery wheels be sprayed with a diluted nonacid based evaporator coil cleaner or alkaline detergent solution such as 409 NOTE Do not use acid based c...

Page 18: ...Manual 2100 635A Page 18 of 18 FIGURE 13 Hub Assembly with Ball Bearings...