Getting Other Information and Publications

These publications can help you install the air
conditioner or heat pump. You can usually find these at
your local library or purchase them directly from the
publisher. Be sure to consult current edition of each
standard.

National Electrical Code ....................... ANSI/NFPA 70

Standard for the Installation ............... ANSI/NFPA 90A
of Air Conditioning and
Ventilating Systems

Standard for Warm Air ........................ ANSI/NFPA 90B
Heating and Air
Conditioning Systems

Load Calculation for ............................. ACCA Manual J
Residential Winter and
Summer Air Conditioning

Duct Design for Residential ................ ACCA Manual D
Winter and Summer Air
Conditioning and Equipment
Selection

FOR MORE INFORMATION, CONTACT
THESE PUBLISHERS:

ACCA

Air Conditioning Contractors of America

1712 New Hampshire Avenue NW
Washington, DC 20009
Telephone: (202) 483-9370
Fax: (202) 234-4721

ANSI

American National Standards Institute

11 West Street, 13th Floor
New York, NY 10036
Telephone: (212) 642-4900
Fax: (212) 302-1286

ASHRAE American Society of Heating Refrigerating,

and Air Conditioning Engineers, Inc.

1791 Tullie Circle, N.E.
Atlanta, GA 30329-2305
Telephone: (404) 636-8400
Fax: (404) 321-5478

NFPA

National Fire Protection Association

Batterymarch Park
P.O. Box 9101
Quincy, MA 02269-9901
Telephone: (800) 344-3555
Fax: (617) 984-7057

Manufactured under the following U.S. patent numbers:

5,485,878;    5,301,744;    5,002,116;

4,924,934;    4,875,520;   4,825,936

Summary of Contents for WA301

Page 1: ...CKAGED AIR CONDITIONER INSTALLATION INSTRUCTIONS Manual No 2100 192M Supersedes 2100 192L File Volume III Tab 16 Date 05 13 02 Bard Manufacturing Company Bryan Ohio 43506 Since 1914 Moving ahead just...

Page 2: ...General 5 Duct Work 5 Filters 5 Fresh Air Intake 6 Condensate Drain 6 Installation Instructions Wall Mounting Information 7 Mounting the Unit 7 Top Outlet Only 7 Wiring Main Power 7 Wiring Low Voltag...

Page 3: ...ACCA Manual D Winter and Summer Air Conditioning and Equipment Selection FOR MORE INFORMATION CONTACT THESE PUBLISHERS ACCA Air Conditioning Contractors of America 1712 New Hampshire Avenue NW Washing...

Page 4: ...e latest revision Article 310 for power conductor sizing CAUTION When more than one field power conductor circuit is run through one conduit the conductors must be derated Pay special attention to not...

Page 5: ...odels only TABLE 2 DIMENSIONS OF BASIC UNIT NOMINAL l e d o M h t d i W W h t p e D D t h g i e H H y l p p u S n r u t e R E F G I J K L M N O P Q R S T A B C B 0 3 A W 6 3 A W 0 0 2 8 3 5 2 1 7 1 3...

Page 6: ...M A H U T B S P M A H U T B S P M A H U T B 0 5 8 0 2 5 6 0 7 1 1 8 1 0 0 8 2 1 8 0 2 5 6 0 7 1 1 8 1 0 0 8 2 1 0 8 3 3 3 0 0 3 7 2 8 8 2 5 7 4 0 2 3 3 3 0 0 3 7 2 8 8 2 5 7 4 0 2 0 0 1 6 1 4 0 3 1 4...

Page 7: ...rement of the equipment Air Conditioning Contractors of America ACCA is an excellent guide to proper sizing All duct work or portions thereof not in the conditioned space should be properly insulated...

Page 8: ...drainage FRESH AIR INTAKE All units are built with fresh air inlet slots punched in the service panel If the unit is equipped with the fresh air damper assembly the assembly is shipped already attache...

Page 9: ...nch diameter flat washers on the lag bolts 7 Secure rain flashing to wall and caulk across entire length of top See Figure 3 8 For additional mounting rigidity the return air and supply air frames or...

Page 10: ...lor coded thermostat cable is recommended The connection points are shown in Figure 10 TABLE 5 THERMOSTAT WIRE SIZE r e m r o f s n a r T A V A L F e r i W e g u a G m u m i x a M e c n a t s i D t e...

Page 11: ...it showing 1 4 inch clearance to combustible surfaces FIGURE 4 ELECTRIC HEAT CLEARANCE MIS 277 WARNING WARNING A minimum of 1 4 inch clearance must be maintained between the supply air duct and combus...

Page 12: ...Page 10 FIGURE 5 WALL MOUNTING INSTRUCTIONS MIS 549 FIGURE 6 WALL MOUNTING INSTRUCTIONS MIS 548 SEE FIGURE 3 MOUNTING INSTRUCTIONS SEE UNIT DIMENSIONS FIGURE 1 FOR ACTUAL DIMENSIONS SEE FIGURE 1 FOR...

Page 13: ...Manual 2100 192 Page 11 MIS 550 FIGURE 7 COMMON WALL MOUNTING INSTALLATIONS...

Page 14: ...Manual 2100 192 Page 12 FIGURE 8 LOW VOLTAGE WIRING MIS 1373C...

Page 15: ...elay On a call for heating circuit R W1 make at the thermostat pulling in heat contact for the strip heat and blower operation On a call for second stage heat R W2 makes bringing on second heat contac...

Page 16: ...mmediately The lockout timer will go into a soft lockout and stay in soft lockout until the high pressure switch closes and the delay on break time has expired If the high pressure switch opens again...

Page 17: ...ng in a suction line temperature 6 inches from compressor as shown in Table 8 The suction line temperatures in Table 8 are based upon 80 F dry bulb 67 F wet bulb 50 percent R H temperature and rated a...

Page 18: ...e r P 5 7 0 8 5 8 0 9 5 9 0 0 1 5 0 1 0 1 1 5 1 1 0 2 1 5 2 1 1 0 3 A W B D g e d 5 7 B W g e d 2 6 e d i S w o L e d i S h g i H 4 7 8 1 2 7 7 2 3 2 9 7 7 4 2 1 8 2 6 2 2 8 7 7 2 4 8 2 9 2 5 8 6 0 3...

Page 19: ...e t a l P f f O k n a l B X X X X X X 3 D A F B r e p m a D r i A h s e r F c i r t e m o r a B X X X X X X 3 D A F M r e p m a D r i A h s e r F d e z i r o t o M X X X X X X 3 V R C t s u a h x E h...

Reviews: