Manual 2100-790
Page
45 of 49
TABLE 17
Maximum ESP of Operation
Electric Heat Only
TABLE 18
Electric Heat
Electric
Heat
Nomenclature
Nominal
KW
Total KW and BTUH @ Field-Supplied Voltage
@ 230V (1)
@ 208V (1)
@ 460V
KW
1 PH
Amps
3 PH
Amps
BTUH
KW
1 PH
Amps
3 PH
Amps
BTUH
KW
3 PH
Amps
BTUH
4
4
3.7
16
12,600
3
14.4
10,200
5
5
4.6
20
11.5
15,700
3.8
18
10.4
12,800
4.6
5.8
15,700
6
6
5.5
13.9
18,800
4.5
12.5
15,400
5.5
6.9
18,800
8
8
7.4
32
25,100
6
28.8
20,500
9
9
8.3
20.8
28,300
6.8
18.7
23,000
8.3
10.4
28,300
10
10
9.2
40
31,400
7.5
36.1
25,600
12
12
11
13.9
37,700
15
15
13.8
60
34.6
47,100
11.3
54.1
31.2
38,400
13.8
17.3
47,100
18
18
16.6
41.6
56,500
13.5
37.5
46,100
16.6
20.8
56,500
20
20
18.4
80
62,800
15
72.1
51,200
Values shown are for units equipped with 2" pleated MERV 13
filter.
Model
W18H
W24H
W30H
W36H
-A04
-A05
-A08
-A10
-A15
.50
.50
.50
.50
.50
.50
.50
.50
.50
-B05
-B09
.50
.50
.50
.50
.50
-C05
-C09
.50
.50
.50
.50
.50