7. Coolant procedures
In this phase, the pressurization pump is activated to
fi
ll the pump. Liquid is
fl
ushed through the service kit tube connected to the
tank
fi
lter cap.
7. Disconnect the small hose that is part of the service kit hose to hose “F” (chiller tank return line).
Image 7-11
Disconnecting small service hose to hose ’F”
8. Connect the other end of the service kit hose to the lower metal quick connector of the chiller (create a loop).
Image 7-12
Connecting service hose to lower quick coupler
9. Connect hose “F” (chiller tank return line) to the upper coupler of the pump.
F
Image 7-13
Connecting "F"
10.Top up the tank with the remaining
fl
uid from the service kit container. See procedure "Adding coolant to the tank", page 31.
Note:
Only use Barco approved cooling liquid. Refer to the Barco website for spare parts.
11.Follow the service tool wizard to
fi
ll the entire coolant circuit.
12.Remove the service kit hoses.
13.Mount the insulation cover.
30