Linking via the RS232 in/out
The constant light output of projectors in a chain (maximum 12 projectors) can be set to the same value by linking the projectors via
the RS232 connector.
To the RS232in of the first projector, a terminator must be connected (
Z3498823
). The out of the first must be connected to the in
of the next projector, etc.
All projectors must have a different projector address between 1 and 12.
All must have the same baud rate and RS mode.
The constant light output setting of one projector must be in the master position. All others must be in the slave position.
Proj 1
Proj 2
Proj 3
Proj 4
in
in
in
in
out
out
out
RS
RS
RS
Terminator
Image 9-7
Principal diagram : linking via RS port
Linking via the Comm port
The constant light output of the projectors can be set to the same value by linking the projectors via the Comm port and using one
or more Comm 800 splitters (See Connections, Linked System).
120
R5976654 SLM R12+ 27/01/2005
Summary of Contents for SLM R12
Page 1: ...SLM R12 Owner s manual R9010171 R5976654 05 27 01 2005...
Page 4: ......
Page 8: ...Table of contents 4 R5976654 SLM R12 27 01 2005...
Page 36: ...3 Installation Guidelines 32 R5976654 SLM R12 27 01 2005...
Page 62: ...5 Getting Started 58 R5976654 SLM R12 27 01 2005...
Page 98: ...7 Random Access Adjustment Mode 94 R5976654 SLM R12 27 01 2005...
Page 136: ...10 Programmable Function Keys 132 R5976654 SLM R12 27 01 2005...
Page 140: ...A Standard Source set up Files 136 R5976654 SLM R12 27 01 2005...
Page 154: ...Glossary 150 R5976654 SLM R12 27 01 2005...