2. Basic Commands
Command
Command [0]
\xf5
Data (optional)
Data[0] = byWindow
Data[1], Data[2] = wValue = word describing the settings of the AutoImage function
The 4 bits of the first byte (lsb) are used.
bit7
bit6
bit5
bit4
bit3
bit2
bit1
bit0
-
-
-
-
Start pixel-line
Phase
Contr/Bright
TotalPixels
Table 2-264
byte description
Example
executes Autoimage on the window which has the focus (the data bytes are ommited).
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\xf5
Checksum
\xf6
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Checksum
\x07
Stop
\xff
2.41 Blanking
Overview
•
•
•
•
•
•
•
•
•
R5976884 RLM SERIES 04/04/2006
79