2. Basic Commands
Example
Reads the Maximum Tint value of the projector, the awnser being
\x00\xb4
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x27
Command[1]
\x04
Checksum
\x32
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Checksum
\x07
Stop
\xff
Receive (Answer)
Start
\xfe
Projector address
\x01
Command[0]
\x27
Command[1]
\x04
Data [0]
\x00
Data [1]
\xb4
Checksum
\xe0
Stop
\xff
2.7.25
Gamma, increment
Description
Increments the Gamma by one.
Command
Command [0]
\x22
Command [1]
\x70
2.7.26
Gamma, decrement
Description
Decrements the Gamma by one.
R5976884 RLM SERIES 04/04/2006