
3. Advanced Commands
Commands
read minimum:
Command [0]
\x26
Command [1]
\x81
read maximum:
Command[0]
\x27
Command[1]
\x81
Returned Data
Data [0]...Data[3] = double word (4 bytes) = min/max value
Data[4] = byte describing the decimal part (2 digits)
min size = 5%
max size = 135.733 %
3.12.2
Minimum/Maximum window X position, Read
Description
Reads the minimum/maximum (range) zoom window X position.
Commands
read minimum:
Command [0]
\x26
Command [1]
\x82
read maximum:
Command[0]
\x27
Command[1]
\x82
Returned Data
Data [0]...Data [3] = double word (4 bytes) = min/max value
Data [4] = byte describing the decimal part (2 digits)
3.12.3
Minimum/Maximum window Yposition, Read
Description
Reads the minimum/maximum (range) zoom window Y position.
Commands
read minimum:
Command [0]
\x26
Command [1]
\x83
read maximum:
Command[0]
\x27
Command[1]
\x83
R5976884 RLM SERIES 04/04/2006
119